N1-4. EXT TEST
This menu is used to check the NETWORK
connector.
With the power to this unit turned off, short
between pins No. 1 (Tx+) and No. 3 (Rx+) and
between pins No. 2 (Tx-) and No. 6 (Rx-) of
the NETWORK connector.
(Be sure to turn off the power to this unit when
shorting these pins.)
Start up the self-diagnostic function and select
this menu.
Note) Be sure to return the shorted pins to their
original condition after executing this test.
8
7
6
5
4
3
NETWORK connector
N1-5. PHY TEST
Communication and bus line connection
between PHY (IC513) and VNP2 (IC504) are
checked.
N1-6. LINE NOISE 10
Not for service.
N1-7. LINE NOISE 100
Not for service.
N 1 - 4
E X T T E S T : O K
2
1
N 1 - 5
P H Y T E S T : O K
N 1 - 6
L I N E N O I S E 1 0
N 1 - 7
L I N E N O I S E 1 0 0
RX-V1067/HTR-8063/RX-A1000
N1-4. EXT TEST
NETWORK コネクタの送受信テストを行いま
す。
本機の電源を切った状態で、NETWORK コネク
タの 1 ピン (Tx+) と 3 ピン (Rx+) 、 2 ピン (Tx-)
と 6 ピン(Rx-)をショートさせます。
(ショートさせるときは必ず本機の電源を切っ
てください。 )
ダイアグを起動して本メニューを選択します。
注意) 検査後、ショートしたピンを必ず元の状態に
戻してください。
OK: Normal / 正常
NG: Abnormal / 異常
N1-5. PHY TEST
PHY(IC513)と VNP2(IC504)の通信・バス
ラインの接続をチェックします。
OK: No error detected / 不良検出なし
NG: An error is detected / 不良検出あり
N1-6. LINE NOISE 10
サービスでは使用しません。
N1-7. LINE NOISE 100
サービスでは使用しません。