L4
01
Check and
Check the main motor operation
remedy
with SIM 25-1.
Check the harness and the
connector between the MCU PWB
and the main motor.
10
Content
Job separator motor trouble
Details
When the home is not detected
within 2.5 sec after the job
separator tray starts to move
upwards.
Cause
The job separator upper limit
detection sensor is defective.
The job separator motor is
defective.
The job separator motor periphery
circuit is defective.
The condition of the MCU PWB
JP5 is wrong.
Check and
Check the job separator operation
countermeas
by means of SIM3-2 and 4.
ure
Check the harnesses and
connectors.
Check whether the condition of
the MCU PWB JP5 is correct.
L6
10
Content
Polygon motor lock
Detail
The lock signal (the specified
rotation speed signal) is not
supplied within the specified time
(about 6 sec)after starting the
polygon motor rotation.
Cause
LSU connector disconnection or
harness disconnection in the LSU.
Check and
Check the operation of the
remedy
polygon motor with SIM 25-10.
Check the harness and the
connector connection.
LSU replacement
L8
01
Content
Zero cross pulse (FW) trouble
Detail
Zero cross pulse width is shifted
by 55Hz ± 10% or more.
Cause
MCU PWB defect
Power supply unit breakdown
Check and
Check the harness and the
remedy
connector.
MCU PWB replacement
Power supply unit replacement
U2
04
Content
EEPROM serial communication
error
Detail
Error in communication with
EEPROM
Cause
EEPROM failure
Installation of uninitialized EEPROM
MCU PWB EERPOM access
circuit failure
Check and
Check that the EEPROM is
remedy
properly set.
To prevent against loss of
counter/adjustment values, record
the values with simulation.
U2 trouble cancel with SIM 16
MCU PWB replacement
Detail of trouble
AR-162 TROUBLE CODE LIST – 7
Main
Sub
code
code
U2
11
Content
Counter check sum error
Detail
Counter check sum value stored
in the EEPROM is abnormal.
Cause
EEPROM failure
Control circuit hung up by noises
MCU PWB EEPROM access
circuit defect
Check and
Check that the EEPROM is
remedy
properly set.
To prevent against loss of
counter/adjustment values, record
the values with simulation.
U2 trouble cancel with SIM 16
MCU PWB replacement
12
Content
Adjustment value check sum error
(EEPROM)
Detail
Adjustment value data area check
sum error
Cause
EEPROM failure
Control circuit hung up by noises
MCU PWB EEPROM access
circuit failure
Check and
Check that the EEPROM is
remedy
properly set.
To prevent against loss of
counter/adjustment values, record
the values with simulation.
U2 trouble cancel with SIM 16
MCU PWB replacement
40
Content
CRUM communication error
Detail
Toner cartridge CRUM data read
error
Cause
A toner cartridge of a different
destination is installed.
EEPROM trouble
Check the destination setup.
Toner cartridge CRUM PWB trouble
MCU PWB trouble
CRUM connector disconnection
Check and
Install a specified toner cartridge.
remedy
Check the SIM 26-6 setup.
Replace the EEPROM.
Replace the toner cartridge.
Replace the MCU PWB.
Check connection of the CRUM
connector.
Execute SIM 16.
U3
29
Content
Mirror base home position error
Detail
Home position is not detected
when starting mirror base shift.
Cause
Mirror unit defect
Mirror home position sensor defect
MCU PWB decfect
Scanner wire disconnection
Check and
Check the scanning operation with
remedy
SIM 1-1.
U9
00
Content
Communication trouble between
MCU and OPE (OPE detection)
Detail
Communication setup error,
framing, parity, protocol error
Detail of trouble