Electrical Specifications - Daikin RZQS71D7V1B Technical Data Manual

Hide thumbs Also See for RZQS71D7V1B:
Table of Contents

Advertisement

2
Specifications
2-2 TECHNICAL SPECIFICATIONS
Refrigerant
Type
Charge
Control
Nr of Circuits
Refrigerant Oil
Type
Charged Volume
Piping connections
Liquid (OD)
Gas
Drain
Piping Length
Additional Refrigerant Charge
Installation height
difference
Max. internunit level difference
Heat Insulation
Defrost Method
Defrost Control
Capacity Control Method
Safety Devices
Standard
Item
Accessories
Quantity
Item
Quantity
Notes

2-3 ELECTRICAL SPECIFICATIONS

Power Supply
Name
Phase
Frequency
Voltage
Voltage range
Minimum
Maximum V
Current
Minimum Ssc (²) value
Recomended fuses
Wiring
For Power
Remark
connections
Supply
For connection
Remark
with indoor
Power Supply Intake
Notes
• Outdoor Units • R-410A • RZQS-DV1
RZQS71D7V1B
kg
l
Quantity
Type
Diameter (OD) mm
Quantity
Type
Diameter (OD) mm
Quantity
Type
Diameter (OD) mm
Minimum
m
Maximum
m
Equivalent
m
Chargeless
m
kg/m
Maximum
m
m
Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature :
RZQS71D7V1B
Hz
50
V
V
198
264
kVa
A
20
(1) European/international technical standard setting the limits for harmonic currents produced by equipment
connected to public low-voltage system with input current > 16A smaller than or equal to 75A per phase.
• Split Sky Air • Outdoor Units
RZQS100D7V1B
R-410A
2.75
3.7
Expansion valve (electronic type)
1
1
FVC50K
Daphne FVC68D
0.75
1.0
1
1
Flare connection
9.52
9.52
1
1
Flare connection
15.9
15.9
3
3
Hole
26
26
5
5
30
50
40
70
30
30
see installation manual 4PW49302-1
15
30
0.5
0.5
Both liquid and gas pipes
Pressure equalising
Temperature
Inverter controlled
High pressure switch
Fan motor thermal protector
Fuse
Tie-wraps
2
2
Installation manual
1
1
temperature : 35°CDB, equivalent refrigerant piping : 5m, level difference : 0m.
7°CDB, 6°CWB, equivalent refrigerant piping : 5m, level difference : 0m
RZQS100D7V1B
RZQS125D7V1B
V1
1~
50
220-240
198
264
Dummy
32
see installation manual 4PW49302-1
see installation manual 4PW49302-1
Outdoor unit only
See separate drawings for electrical data
(2) Short-circuit power
Power supply to the FDQ
indoor unit is separate
RZQS125D7V1B
RZQS140D7V1B
3.7
3.7
1
1
Daphne FVC68D
Daphne FVC68D
1.0
1.0
1
1
9.52
9.52
1
1
15.9
15.9
3
3
26
26
5
5
50
50
70
70
30
30
30
30
0.5
0.5
2
2
1
1
RZQS140D7V1B
50
50
198
198
264
264
32
32
3
1
2
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rzqs100d7v1bRzqs140d7v1bRzqs125d7v1b