ADD / EDIT
PARTITIONS
Add/Edit Partition. Default settings has only the first partition enabled. To enable more partitions,
ADD/EDIT PAR
select the Add/Edit partition section, then select the partition. The partition is now enabled.
(0)
The PC4010 can be divided into 4 partitions. This section selects which of the 4 partitions the
WHICH PARTITION
installer is programming.
(1)
(4)
Each partition has its own 4 digit customer account number that will be transmitted to the
CUSTOMER ID CODE
monitoring station when a reporting code is sent. The monitoring station can then identify the
(0)
customer. Where a zero digit is required, use Hex A to transmit ten pulses. The receiver at the
monitoring station interprets ten pulses as a zero. If a three digit code is required, enter [0] as the
last digit. [0] represents a null digit, no pulses will be transmitted.

Partition Toggles

Enabling or disabling options for individual partitions.
PAR TOGGLES
(1)
[F] Key Enabled?
[F] ENABLED
YES = The [F]ire key is enabled.
Y
NO = The [F]ire key is disabled.
(See "KEYPAD TOG OPT".)
[A] Key Enabled?
[A] ENABLED
YES = The [A]uxiliary key is enabled.
Y
NO = The [A]uxiliary key is disabled.
(See "KEYPAD TOG OPT".)
[P] Key Enabled?
[P] ENABLED
YES = The [P]anic key is enabled.
Y
NO = The [P]anic key is disabled.
(See "KEYPAD TOG OPT".)
Display Clock?
DISPLAY CLOCK
YES = The time and date will be displayed on every keypad of the partition instead of the
Y
NO = No clock display.
Display Delay Exit Time?
DISP EXIT TIME
YES = The exit delay time remaining will be displayed in the lower corner on all keypads on the
Y
NO = No exit time display.
Bypass require code?
BYPAS REQ CODE
YES = Bypassing zones requires a valid access code ([ ][1][code]), either a System Master
Y
NO = No access code required to bypass zones ([ ][1]).
Auto Arming/Auto Disarming?
AUTOARM/DIS
YES = Auto Arm control enabled.
Y
NO = Auto Arm control disabled. If disabled, the user will not be able to enter the Auto Arm
Note: The panel will not auto arm or auto disarm, if there is a loss of time trouble present on
the system.
Auto Arm Abort requires Access Code?
ABORT REQ CODE
YES = An access code must be entered during the autoarm prealert to abort the auto arm.
N
NO = Pressing any key during the prealert will abort the auto arm.
Note: If the Auto Arm Abort Code is programmed it will be sent for one of these conditions.
Auto Arm Abort requires access code must be enabled for CTT arming to function properly.
"ENTER CODE TO ARM SYSTEM" message after 10 seconds of no key presses.
partition during the exit delay.
code or an access code assigned to that partition.
control menu in the [ ][6] user functions.