Advertisement

AXIS Q1775-E Network Camera
Events
-
Audio Detection – Trigger the rule when audio is detected. See Audio Detection on page 34.
-
Live Stream Accessed – Trigger the rule when any stream is accessed and during edge storage playback.
This can for example be used to send notifications.
-
Shock Detection – Trigger the rule when the Axis product detects it has been tilted or hit. See Shock Detection
on page 32.
-
Tampering – Trigger the rule when tampering is detected. See Camera Tampering on page 32.
Hardware
-
Network – Trigger the rule if network connection is lost or restored. This can for example be used to start
recording to the SD card.
-
Temperature – Trigger the rule if the temperature falls outside or inside the operating range of the product. This
can for example be used to send maintenance notifications.
Input Signal
-
Digital Input Port – Trigger the rule when an I/O port receives a signal from a connected device. See I/O
Ports on page 61.
-
Manual Trigger – Trigger the rule using the Manual Trigger button in the Live View page. See Controls on
the Live View Page on page 12. This can for example be used to validate actions during product installation
and configuration.
-
Virtual Inputs – can be used by a VMS (Video Management System) to trigger actions. Virtual inputs can, for
example, be connected to buttons in the VMS user interface.
PTZ
-
Moving – Trigger the rule when the camera view moves due to a PTZ operation. This can for example be used
as an additional condition to prevent an action rule triggered by motion detection to record video while the
camera view moves due to a PTZ operation.
-
Preset Reached – Trigger the rule when the camera stops at a preset position. This can be for example be used
with the Send Images action to upload images from the preset position.
-
Ready – Trigger the rule when the PTZ functionality is ready to be used. This can for example be used to steer
the camera to a specific preset position when the product is started.
Storage
-
Disruption – Trigger the rule if storage problems are detected, for example if the storage device is unavailable,
removed, full, locked or if other read or write problems occur. This can for example be used to send maintenance
notifications.
-
Recording – Triggers the rule when the Axis product records to the storage device. The recording status trigger
can be used to notify the operator, for example by flashing LED lights, if the product has started or stopped to
record to the storage device. Note that, this trigger can be used only for edge storage recording status.
System
-
System Ready – Trigger the rule when the product has been started and all services are running. This can for
example be used to send a notification when the product restarts.
Time
-
Recurrence – Trigger the rule periodically. See Set Up Recurrences on page 46. This can for example be used to
upload an image every 5 minutes.
-
Use Schedule – Trigger the rule according to the selected schedule. See Create Schedules on page 46.