Sanyo PLC-WTC500AL Service Manual page 63

Hide thumbs Also See for PLC-WTC500AL:
Table of Contents

Advertisement

Electrical Adjustment
Grp / No.
Item
20
21
Lamp Warning Time (NORMAL)
22
Lamp Warning Time (ECO)
23
Lamp Warning Time (HIGH)
50
Lamp Replacement Display
51
Filter Warning Display
52
Lamp Counter Reset Times
53
Filter Counter Reset Times
54
Factory Default Executed Times
55
Motor Operation Stop
56
Menu Position (X)
57
Menu Position (Y)
58
Lamp Go Out
70
ADC Device Select for Analog PC 0 = ISL98001, 1 = PW392 AFE
71
ADC Device Select for Component 0 = ISL98001, 1 = PW392 AFE
72
Component/RGB SW
80
Destination
100 Disable Auto Picture Control
120 HDMI HPD/EDID Control in STBY 0: Disable Auto Control, 1: Enable Auto Control
201
Option (Signal)
0
FrameLock Option
1
Dither Enable
204
Simulation mode
0
PW392C Enable
1
PW610 Enable
210
Lamp Control
0
Dimmer SW
1
Manual Control
2
DIMMER_CTRL_LEVEL1
3
DIMMER_CTRL_LEVEL2
4
DIMMER_CTRL_LEVEL3
5
DIMMER_CTRL_LEVEL4
6
DIMMER_CTRL_LEVEL5
7
DIMMER_CTRL_LEVEL6
8
DIMMER_CTRL_LEVEL7
9
DIMMER_CTRL_LEVEL8
10
DIMMER_CTRL_LEVEL9
11
DIMMER_CTRL_LEVEL10
12
DIMMER_CTRL_LEVEL11
13
DIMMER_CTRL_LEVEL12
14
DIMMER_CTRL_LEVEL13
15
DIMMER_CTRL_LEVEL14
16
DIMMER_CTRL_LEVEL15
17
DIMMER_AVERAGE_POINT
18
DIMMER_AVERAGE_DATA
19
DIMMER_LEVEL_AUTO
20
DIMMER_LEVEL_NORMAL
21
DIMMER_LEVEL_ECO
23
VOLTAGE_LEVEL
24
DIMMER_LEVEL_HIGH
220
Projector Error Log
0
Warning_Log_1
:
:
49
Warning_Log_50
50
Warning_Log Reset
235
Shutter
0
PRE_MOTION
1
CMP_TRM
2
OUT_DLY_TRM
3
CMP_CHK_CNT
4
OPEN_DLY
5
CLOSE_DLY
6
Position Check Time
Function
1:On 0:Off
1:On 0:Off
Read only
Read only
Read only
0: Enable 1: Disable
X Offset
Y Offset
Lamp goes out
Auto Component/RGB Switch 0: Disable, 1: Enable
Disable G200-70/71 if this function is set to "Enable".
Language Set at Shipping 0:English 1:Japanese
0 : Normal operation 1 : Auto Picture Control Off
Frame Lock Setting 0: OFF, 1: Normal (Auto)
0: Disable 1: Enable
0: Off, 1: On
0: Off, 1: On
0:Auto 1:Manual
Lamp Power Manual Control (DIMMER_CTRL_LEVEL
0(Dark)~15(Bright))
Y Level1 Data for Dimmer
Y Level2 Data for Dimmer
Y Level3 Data for Dimmer
Y Level4 Data for Dimmer
Y Level5 Data for Dimmer
Y Level6 Data for Dimmer
Y Level7 Data for Dimmer
Y Level8 Data for Dimmer
Y Level9 Data for Dimmer
Y Level10 Data for Dimmer
Y Level11 Data for Dimmer
Y Level12 Data for Dimmer
Y Level13 Data for Dimmer
Y Level14 Data for Dimmer
Y Level15 Data for Dimmer
Y Average Point
Y Average Data (Read only)
Current Y Level (Read only)
Dim Level at Normal
Dim Level at Eco
Lamp Voltage (Read only)
Dim Level at High
Latest Error log
:
50th Error log
Log is cleared when the value is set to 10.
Shutter Warm - up Operation (0: Yes, 1: No)
Chattering Detecting Term
Output Term
Count of Information Sync
Open Output Delay
Close Output Delay
Position Check Time
Range
0 - 10
1-16
1-16
1-16
0 - 1
0 - 1
0 - 255
0 - 255
0 - 255
0 - 1
0 - 1024
0-1024
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0-1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 15
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 16
-
-
0 - 15
0 - 15
-
0 - 15
0 - 32767
:
0 - 32767
0 ~ 10
0 - 1
0 - 32767
0 - 32767
0 - 15
0 - 63
0 - 63
1 - 255
-63-
Initial
Note
0
5
6
4
1
1
0
0
0
0
0
0
0
0
1
1
0
Initial: 1 Shipping 0
1
1
1
0
0
0
0
7
14
21
28
35
42
49
56
63
70
77
84
91
98
105
4
-
-
8
0
-
15
0
:
0
0
Initial: 1 / Shipping: 0
7000
15000
0
0
0
50

Hide quick links:

Advertisement

Table of Contents
loading