OPERATING INSTRUCTIONS 120 VOLT AC MODE
CAUTION: DO NOT OVERINFLATE ITEM BEING INFLATED.
Place inflator evenly on flat surface.
Insert the 120 Volt AC Power Cord into a grounded 120 Volt AC Outlet and this will
automatically provide continuous 120 volt current to your inflator.
Connect the Quick Connect Valve Adaptor to item you are inflating and push down the
Valve Lock Lever to secure the connection.
Push the Power Selector Switch in the top left corner of the inflator to the 120 Volt,
position. (Please see Image #2 below).
The Digital Pressure Gauge will display the current pressure of the item you are inflating.
When the LCD readout screen is displaying the current PSI, the LCD readout is static.
Press the ▲ button on the Digital Pressure Gauge to set the desired PSI. The Digital
Pressure Gauge preset range is 3 PSI minimum to 120 PSI maximum. When the LCD
readout screen is displaying the target PSI, the LCD readout will blink 3 times at the
desired preset level and it will then change back to the current PSI level of the item you are
inflating.
Note: If the current pressure of the item you are inflating is greater than the preset level,
the inflator will not turn on.
To turn the inflator on, push the Run/Pause,
changed during inflation, simply press the ▲ or ▼buttons to new desired PSI level.
The inflator will shut off automatically at the desired preset PSI level that you have
programmed into the Digital Pressure Gauge.
Note: The inflator has a tolerance of + or – 2 PSI and will automatically shut off
accordingly.
To stop the inflator before it reaches the preset PSI level, push the Run/Pause button. To
resume inflation, simply press the Run/Pause button again.
Note: Disconnecting inflator from 120 Volt AC Outlet will clear the previous preset PSI setting.