InFocus X2 Service Manual page 16

Hide thumbs Also See for X2:
Table of Contents

Advertisement

Remove the Elevator Actuator and Spring
1
Remove the elevator shaft.
2
Slide the actuator and spring out of the elevator housing. Remove the spring from the actuator
once it is accessible.
3
Twist the actuator so that you can slide the it out of the bottom case.
Assembly Notes
Before inserting the actuator into the elevator housing, slide the spring onto the end.
When you install the elevator shaft, make sure that the grooves on the elevator shaft face the
lamp housing. Then depress the elevator actuator and insert the shaft into the elevator housing.
Make sure the teeth on the shaft engage the actuator.