InFocus X2 Service Manual page 13

Hide thumbs Also See for X2:
Table of Contents

Advertisement

Replace and tighten the two M3x25 Plastite Phillips screws. Do not over tighten the screws.
Make sure that the cables are clear of the fan blades.
Removing the 80mm Fan
1
Remove the two M3x30 Plastite Phillips screws that fasten the fan to the lamp housing.
2
Lift the fan away from the lamp housing.
Assembly Notes
Position the fan against the lamp housing with fan label facing the lamp housing and the cable
recess at the bottom right side. The cables should exit the fan at the recess on the side opposite
the label.
X2 Service Manual