Adjustment
12
Knife height
.06.02
12 - 34
Requirement
When the adjustment lever 1 is set at "0" and the knife is at the top of its stroke, the top
edges of the needle plate and knife should be at the same level.
3
2
Fig. 12 - 33
Set adjustment lever 1 at "0".
Remove cover cap 2 and turn the motor impeller wheel until the knife is positioned at its
t.d.c.
Adjust linkage rod 3 (screw 4) in accordance with the requirement.
1
4