I-21
Horizontal lines
Possible cause
Step
Paper tray
1
contacts
I-22
Light rain
Possible cause
Step
Drum unit failure
1
Drum
2
connection
failure
High-voltage
3
power supply
PCB failure
Check
Are the ground contacts on the
back of the paper tray
connecting correctly?
Check
Is the problem solved after
replacing the drum unit?
Is the contact between the
drum unit and machine
connected correctly?
Is the problem solved after
replacing the high-voltage
power supply PCB?
6-51
MFC-8440/8840D/8840DN, DCP-8040/8045D/8045DN
Result
Remedy
No
Clean the contacts.
Remedy
Result
Yes
Replace the drum
unit.
No
Clean contact
electrode both on the
drum unit and in the
machine.
Yes
Replace the high-
voltage power supply
PCB.
SERVICE MANUAL
Ground
contacts
(7)
Ground
contact
(8)