Troubles And Solutions - Carrier 42/38KCJ024713 Technical & Service Manual

Free stand air conditioner
Table of Contents

Advertisement

P9
Protection of defrosting or anti-cold wind
E1
Open-circuit and short-circuit of temperature sensors T1
E2
Temp. sensor T2 on indoor evaporator is open circuit or short circuit
E3
The condenser temperature sensor T3 is open or short
E6
Protection of outdoor unit
8.2.1 LEDs for the indication of outdoor trouble
In normal operation, LEDs emit no light and they will flash at a frequency of 5 Hz when
trouble occurs. Their codes are listed in the following table:
LED1
LED2
Off
Off
On
Off
Off
On
On
On

8.3 Troubles and Solutions

Before calling for service, please review the following list of common problems and
solutions.
If any of the following conditions occur, check your unit and resolve corresponding
problems referring to given remediation. If the trouble can't be settled contact our
dealer.
Trouble
Cause
Unit does not
Power failure.
start
Power switch is open.
Fuse of power switch may have
blown.
Batteries remote controller are
exhausted.
The time is not start-up time you
have set.
Air flowing
Temperature is not set correctly.
normally with
low
Door or window is open.
cooling(heating)
Air filter is blocked with dust or
effect
dirtiness.
Inlet/outlet of indoor/outdoor units
are blocked.
Inlet/outlet of indoor/outdoor units
are blocked.
LED3
Contents
On
Ok
On
Phase sequence error
On
Overload of current
On
Lack of phase
24
Exploded view & spare-part
Solutions
Wait for the comeback of
power
Switch on the power
Replace the fuse
Replace the batteries
Wait or cancel the time set.
Set the temperature
properly.
Close door and window.
Clean the air filter.
Clear all blockages.
Clear the blockage, then
restart your operation.