Following Symptoms Are Not Air Conditioner Troubles - Carrier 40MBQB09D--3 Owner's Manual

Ducted heat pump split system
Hide thumbs Also See for 40MBQB09D--3:
Table of Contents

Advertisement

The air-in side should face up when using vacuum cleaner.
(Refer to Fig. 5-4)
The air-in side should face down when using water.
(Refer to
Fig. 5-3)
Symptom 3.2: Indoor unit, outdoor unit
[]
When the system is changed over to heating operation
after
defrost operation moisture generated
from defrosting
becomes
steam and is exhausted.
CAUTION
Do not dry out the air filter under direct sunshine or with fire.
5. Re-install the air filter
6. install and close the air-in grill in the reverse order of step 1
and 2 and connect the control box cables to the corresponding
terminators of the main body.
9. FOLLOWING
SYMPTOMS
ARE NOT AIR
CONDITIONER
TROUBLES
Sptom
4: Noise of air conditionerscooling
Symptom 4.1: Indoor unit
[]
A continuous
low "shah" sound is heard when the system is in
cooling operation or at a stop.
When the drain pump (optional accessories)
is in operation,this
noise is heard.
[]
A "pishi-pishi"
squeaking sound is heard when the system stops
after heating operation.
Expansion
and
contraction
of
plastic
parts
caused
by
temperature change make this noise.
Symptom
1" The system
does
not operate
[]
The air conditioner
does not start immediately
after the ON/OFF
button on the romote controller is pressed,
If the operation lamp lights, the system is in normal condition,To
prevent
overloading
of
the
compressor
motor,
the
air
conditioner starts 3 minutes
after it is turned ON,
If the operation
lamp and the "PRE-DEF
indicator(cooling
and
heating type) or fan only indicator(cooling
only type)" light, it
means you choose the heating model, When just starting, if the
compressor
has not started, the indoor unit
appears "anti cold
wind" protection because of its overlow outlet temperature,
Symptom
2: Change
into the fan mode
during
cooling
mode
[]
In order to prevent the indoor evaporator
frosting, the system
will change into fan mode automatically,
restore to the cooling
mode after soon,
[]
When the room temperature
drops to the set temperature,
the
compressor
goes off and the indoor unit changes to fan mode;
when the temperature
rises up, the compressor
starts again. It
is same in the heating mode.
Symptom 4.2: Indoor unit, outdoor unit
[]
A continuous
low hissing sound is heard when the system is in
operation,
This is the sound of refrigerant gas flowing through both indoor
and outdoor units,
[]
A hissing sound which is heard at the start or immediately after
stopping operation or defrost operation,
This is the noise of refrigerant
caused
by flow stop or flow
change,
Symptom 4.3: Outdoor
unit
[]
When the tone of operating noise changes.
This noise is caused by the change of frequency.
Symptom
5: Dust comes
out of the unit
[]
When the unit is used for the first time in a long time.
This is because dust has gotten into the unit.
Symptom
6: The unit can emit odors
[]
The unit can absorb the smell of rooms, furniture,
cigarettes,
etc., and then emit it again.
Symptom
3: White
mist comes
out of a unit
Symptom
3.1 : Indoor
unit
When humidity is high during cooling operation
If the interior of
an indoor
unit is extremely
contaminated,
the temperature
distribution
inside a room becomes
uneven, It is necessary
to
clean the interior of the indoor unit, Ask your dealer for details
on cleaning the unit, This operation requires a qualified service
erson
Symptom
7: The outdoor
unit fan does
not
spin.
[]
During operation.
The speed of the fan is controlled in order to
optimize product operation.
21