DIMENSIONS
CEILING MOUNTED CASSETTE TYPE
[FCQN71-140KVEA]
B
860~910(Ceiling opening space) (Note 4)
300
710(Suspension position)
or less
420
9
420
[FCQN71KVEA]
55
840
340
80
2 100 = 200
80
124
20
C/L
157
Suspension bolt
350
4-M8~M10
280
330
Connection position
of branch duct
(round shape type)
[FCQN100-140KVEA]
55
840
340
2 100 = 200
80
80
160
C/L
20
157
Suspension bolt
350
4-M8~M10
280
Connection position
330
of branch duct
(round shape type)
Notes:
1
Sticking location for manufacture's label
manufacture's label for indoor unit:
Suction grille inner side's electric components box's lid surface
manufacture's label for decoration panel :
Decoration panel's corner decoration cover inner surface
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller
in detail.
3
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4
Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less
between the indoor unit and the ceiling opening so that
the panel overlap allowance can be ensured.
5
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
(Unit: mm)
[FCQN71-140KVEA]
8
Pipe Connection
Side
C
Drain Connection
Side
[FCQN71KVEA]
16-M4 Prepared hole
55 Connection position
3
of branch duct
55
(square-shaped type)
81 2x100=200
64
50
35 or less
(Note 4)
Connection position
4
1
2
of branch duct
(round shape type)
[FCQN100-140KVEA]
16-M4 Prepared hole
3
55
55
Connection position
of branch duct
81
(square-shaped type)
64
50
35 or less
(Note 4)
Connection position
4
1
2
of branch duct
(round shape type)
81
950
Note 2
B
6
7
A
arrow view
20-M4 Prepared hole
840
55
85
5
124
35 or less
256
(Note 4)
157
Connection position
350
of branch duct
(square-shaped type)
A
840
55
27-M4 Prepared hole
2 100 = 200
85
160
5
35 or less
256
(Note 4)
157
Connection position
350
of branch duct
(square-shaped type)
A
[FCQN71KVEA]
[FCQN100-140KVEA]
81
2x100=200
85
Connection position
of branch duct
124
(round shape type)
C/L
16-M4 Hole
157
Connection position
350
of branch duct
(square-shaped type)
arrow view
B
[FCQN71KVEA]
160
124
Connection position
Connection position
of branch duct
109
of branch duct
(square-shaped type)
95
(square-shaped type)
20-M4
Prepared hole
C/L
Connection position
Connection position
of branch duct
of branch duct
(round shape type)
(round shape type)
90
Connection position
Connection position
183
of fresh air intake kit
of fresh air intake kit
C
arrow view
(direct installation type)
(direct installation type)
Required space
1500mm or more
200mm or more
1500mm
or more
200mm
or more
1500mm or more
When the blow-off grille is closing.
The required space is 500mm or more.
When uniting and closing a corner part
(both right and left of the blow-off grille to close),
it is 200mm or more.
1
Liquid pipe connection
Gas pipe connection
2
3
Drain pipe connection
4
Power-source wiring and a unit wiring connection
5
Connection wiring / remote control wiring connection
6
Air-outlet
7
Suction grille
8
Corner decoration cover
9
Drain hose (accessory)
Connection position
of branch duct
2 100 = 200
85
(round shape type)
160
C/L
16-M4 Hole
157
Connection position
350
of branch duct
(square-shaped type)
arrow view
[FCQN100-140KVEA]
160
167
93
67
95
29
20-M4
Prepared hole
C/L
90
196
C
arrow view
1500mm
or more
14