Fill Cup; Ejector Blades Or Stripper; Accessing Control Box - Amana SXD25S2 Service

Side-by-side “s” model refrigerators
Table of Contents

Advertisement

Ice Maker

Fill Cup

Remove module and support assembly. Remove
ejector blades and shut-off arm. Pull fill cup from
mold.

Ejector Blades or Stripper

Remove module and support assembly. When rein-
stalling ejector blades, realign "D" coupling with mod-
ule cam.

Accessing Control box

To remove motor and contact assembly from control box,
take out three screws (arrows) and pull free after discon-
necting shut-off arm.
Mold and Heater Screw Access Ports
December1997
Rotating blades or drive gear will ruin main assem-
bly.
There are several switches which will jam if manually
turned counterclockwise and gears will be destroyed if
turned clockwise. To advance the ice maker into the
cycle, use a jumper to bridge H to R and unless the
motor is defective, it will run. (The shut-off arm must
be in the on position.)
NOTE: There are several slotted shafts on the motor
assembly board. Do not under any circumstances in-
sert a screwdriver and attempt to turn these shafts.
The slots are to permit assembly only.
NOTE: There are not repairable or replaceable com-
ponents in the module. Unless you are replacing the
module, there should be no need to remove it when
diagnosing or repairing the ice maker.
Water valve
energized
7.5 seconds
140cc fill
about 11:00
o'clock
Thermostat
opens in this
6:00 o'clock
range of
position
rotation then
heater is off
69
Ejector blade stop position
(about 1:30 o'clock
Start position:
thermostat closes,
motor on,
heater on
Ejector stall on ice,
Motor on (30 seconds
to 5 minutes) about
4:00 o'clock
RS1300003 Rev. 0