Compressor Run Capacitor (Control Housing
Mounted)
1. Remove toe grille.
2. Remove mounting screw securing timer/capacitor
housing to conenser.
3. Remove top from housing by removing screw
securing top to housing.
4. Disconnect wiring to capacitor.
WARNING
To avoid electrical shock which can cause severe
personal injury or death, discharge capacitor before
handling.
5. Remove nut securing capitor to housing and
remove capacitor.

Overload and Relay

1. See Compressor, Condenser, Condenser Fan
Access.
2. Remove bale strap from compressor terminal
cover and remove cover.
3. Remove electrical leads from overload and relay.
4. Pull overload lead off compressor common termal
and pull relay off compressor start and run
terminals.

Condenser Fan Blade

1. See Compressor, Condenser, Condenser Fan
Access.
2. Remove nut from motor shaft.
3. Remove fan blade. Replace rubber washer behind
fan blade when reassembling.

Condenser Fan Motor

1. See Condenser Fan Blade
2. Remove compressor electrical cover and remove
both motor leads from overload and relay and
ground wires.
3. Remove three hex head screws mounting motor to
brackets.
RS1300003 Rev. 0
!
WARNING

Condenser

1. See Compressor, Condenser, Condenser Fan
Access.
2. See Condenser Fan Motor, steps 1-3.
Note:
Condenser is only available as assembly with
base pan.
Drain Tube
1. Remove machine compartment rear cover and heat
exchanger cover.
2. Remove two screws securing condenser fan
shroud to outer case back, if necessary.
3. Unclip machine compartment wire harness from
condenser fan shroud. Unclip drier.
4. Remove one bolt from left and one bolt from right
side of compressor compartment pan.
5. Slide compressor compartment out rear of unit
approximately 3 inches.
6. Remove "P" clamps attaching drain tube to the
ceiling of machine compartment.
7. Pull drain tube off nipple in machine compartment
ceiling.