Care and Cleaning

Before cleaning the unit, unplug and allow the unit to cool.
Body and lid
·
Lid
·
·
·
·
Temperature
sensor
Temperature sensor
·
Body
Dispenser lid
·
Inner lid section
·
·
·
·
Raisin nut dispenser
·
·
·
·
Bread pan and kneading blade
·
·
·
·
·
Kneader mounting shaft
Measuring cup
·
·
1. Be sure that the unit and the bread pan have dried completely before storing.
2. On the interior of the body some discolouration may occur with use.
17
Body and lid should be wiped clean with a damp cloth.
Use only mild liquid detergent.
For baked-on materials, use a non scratch scourer and detergent
on the interior.
Do not use cleansers, steel wool pads, or other abrasive materials.
Do not use benzine, thinner, alcohol, etc.
Wipe gently and avoid deforming the temperature sensor.
Dispenser lid will be very hot after baking. Only remove the lid after it
cools down completely.
To clean, remove the dispenser lid and wash gently with soft sponge.
Do not rub or pull the rubber gasket.
Rubbing and pulling roughly may damage the rubber gasket attached
to the dispenser lid. Inner lid section is not removable.
Do not use any abrasive materials.
If the gasket becomes damaged the dispenser lid should be replaced,
as this will cause the leakage of steam, condensation, or deformation.
(See page 45 for replacement.)
This part is not dishwasher safe.
The dispenser will be very hot after baking. Remove the dispenser
after it cools down completely.
Do not use any harsh cleansers, steel wool pads, or other abrasive
materials or utensils, especially on the non-stick coated surface.
It may scratch the surface and cause ingredients to stick.
Clean the dispenser after each use to avoid build up of residue of
ingredients.
This part is not dishwasher safe, as it may become damaged.
If the kneading blade cannot be easily removed from the pan by
twisting the mounting shaft, pour warm water into the cooled pan and
leave aside for 5 –10 minutes. Remove the blade.
Always remove the blade and wash the pan with mild, liquid detergent
after each use.
DO NOT SUBMERGE THE PAN IN WATER.
Do not use other abrasive materials or otherwise, the pan may be
scratched.
These parts are not dishwasher safe.
Rinse and wipe dry.
This part is not dishwasher safe.
Display Indications for Abnormal Conditions
Reason/Cause
Condition
The unit is hot (above 40˚C/105˚F).
TEMP
appears
This may occur during repetitive use.
on
You must allow the unit to cool down
display.
before reusing.
There has been a 10-minute* or
POWER ALERT
is on
less power cut. (The power plug
display.
has been inadvertently pulled out or
the breaker has activated.)
Or there has been a slight change in
the power supplied to the machine.
There has been a power cut for a
certain period of time. (The length of
is on
time may differ according to the
display.
circumstances.) (Possible causes:
power failure, unplugging of the power
cord, or a malfunctioning of household
fuse or breaker).
Not baked at all, although
Motor protection device has activated.
the operation appears to
This only happens when the unit is
have proceeded.
overloaded and an excessive force
is applied to the motor.
After about 30 minutes, the motor
automatically starts running again.
*Note: In some countries, the power interruption memory may last 20 minutes.
Motor protection device
If the unit is overloaded and an excessive force is applied to the motor, the protection device will
stop the motor. After approximately 30 minutes, the motor will automatically start running again. It is
recommended to restart with fresh ingredients.
If the kneading blade is restricted by hard dough, take out the dough. The
Remedy 1
unit will restart 30 minutes later.
Check to see if the kneader mounting shaft of the bread pan can rotate.
Remedy 2
If it can rotate, restart the bread maker after 30 minutes. If it cannot rotate,
service will be required.
How to reset/restart
Leave the unit as it is.
When the unit has cooled to below 40˚C/105˚F,
TEMP
will disappear from the display window
and the flashing red operation light will go out.
This indicates that the unit is now ready to use.
If the interruption in the power supply is
momentary, the operation will not be affected.
If the power is restored within 10 minutes*,
the bread maker will operate again.
However, the bread may not turn out well.
Remove the dough and start again using all
new ingredients.
Check to see if the kneader mounting shaft can
rotate.
Yes
No
Service will
Make sure you did not use
be required.
too much or too hard/heavy
ingredients, then start again
using all new ingredients.
18