NEC switch User Manual page 3

Nec user's manua switch
Table of Contents

Advertisement

1
PRECAUTION AGAINST ESD FOR SEMICONDUCTORS
Note:
Strong electric field, when exposed to a MOS device, can cause destruction of the gate oxide and
ultimately degrade the device operation.
electricity as much as possible, and quickly dissipate it once, when it has occurred.
Environmental control must be adequate.
recommended to avoid using insulators that easily build static electricity. Semiconductor devices
must be stored and transported in an anti-static container, static shielding bag or conductive
material. All test and measurement tools including work bench and floor should be grounded.
The operator should be grounded using wrist strap. Semiconductor devices must not be touched
with bare hands.
devices on it.
2
HANDLING OF UNUSED INPUT PINS FOR CMOS
Note:
No connection for CMOS device inputs can be cause of malfunction.
provided to the input pins, it is possible that an internal input level may be generated due to
noise, etc., hence causing malfunction. CMOS devices behave differently than Bipolar or NMOS
devices. Input levels of CMOS devices must be fixed high or low by using a pull-up or pull-down
circuitry. Each unused pin should be connected to V
to have a possibility of being an output pin. All handling related to the unused pins must be
judged device by device and related specifications governing the devices.
3
STATUS BEFORE INITIALIZATION OF MOS DEVICES
Note:
Power-on does not necessarily define initial status of MOS device. Production process of MOS
does not define the initial operation status of the device. Immediately after the power source is
turned ON, the devices with reset function have not yet been initialized. Hence, power-on does
not guarantee out-pin levels, I/O settings or contents of registers. Device is not initialized until
the reset signal is received. Reset operation must be executed immediately after power-on for
devices having reset function.
FIP and EEPROM are trademarks of NEC Electronics Corporation.
Windows and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the
United States and/or other countries.
PC/AT is a trademark of International Business Machines Corporation.
HP9000 Series 700 and HP-UX are trademarks of Hewlett-Packard Company.
SPARCstation is a trademark of SPARC International, Inc.
Solaris and SunOS are trademarks of Sun Microsystems, Inc.
NOTES FOR CMOS DEVICES
Similar precautions need to be taken for PW boards with semiconductor
User's Manual U12978EJ3V0UD
Steps must be taken to stop generation of static
When it is dry, humidifier should be used.
or GND with a resistor, if it is considered
DD
It is
If no connection is
3

Advertisement

Table of Contents
loading