W
iring diagram in Handle L
LS0714L (with laser marker)
When connecting power supply cord with electrical
parts in handle, strip the power supply cord to expose
50mm up to 70mm of one inner lead wire for
connecting with Terminal as illustrated to right.
Main switch
Noise suppressor
Insulated connector
Pass the thin lead wires (black and red) with connector
1
of wiring board through the punched hole.
The following lead wires for connecting insulated
2
connector should be put into lead wire holder so thati
nsulated connector does not rise from handle L.
* Lead wire (red) to switch
* Lead wire (blue) to transformer
* Field lead wire (orange)
* Lead wire (white) of noise suppressor
3
Transformer must be mounted so that lead wires
(black and white) face the side of handle R and
are in the side of motor housing.
If these lead wires go over Rib A/B, these are pinched
between the Rib A/B and handle R.
Therefore, fix them with full attention.
4
When putting the lead wires into lead wire holders,
the thin lead wires have to be put under the thick
lead wires so as not to rise from the original position.
Printed wiring board
Rib D
Connector
Punched
hole
Rib B
Rib A
Transformer
Powers supply cord
Terminal block
Receptacles for connecting
to laser switch
Motor housing
5
Power supply cord should be put so that its sheath
portion is between Rib C and the wall of housing L.
6 When putting handle R on housing L,
be careful not to go over lead wires on Rib D.
Otherwise it will happen pinching.
7
When connecting receptacles to laser switch,
be sure to face its wire-accepting side to handle R.
The receptacle with blue colored lead wire should
be close to I mark on the laser switch.
The receptacle with black colored lead wire should
be close to O mark on the laser switch.
See illustration below.
Wire-accepting side
Handle R
Lead wire
(blue)
Lead wire
(black)
P 26/ 26
50-70mm
Power supply cord
Rib C
Terminal block
Laser
switch
Receptacles

Advertisement