2.2.3
removing and replacing
the inner door
(only for the LG 30 and LG 40 model,
see figure 7a).
Mode of operation:
1. Place lip A through the recess on the
right and subsequently slide it down
behind the steel wall. See to it that
both lower lips remain in front of the
metal wall;
2. Press lip B through the recess on the
left;
3. Subsequently slide lip B behind the
steel wall (see drawing 7a).
(only for the LG 50 model, see figure 7b).
Procedure:
1. Turn down both clamps (1).
2. Place the entire door into the
appliance and move the opening
over the burner venturi.
3. Turn both clamps outward (3),
pushing them over the edge of the
burner chamber.

2.3 Pilot adjustment

The pilot can be adjusted by means of
the regulating screw under the plastic
cover on the right hand side of the gas
control block.
Turn the screw clockwise to reduce the
gas pressure and anti clockwise to incre-
ase the pressure. Care should be taken
to ensure the pilot covers the thermocou-
ple element correctly.
2.4 Putting out of
operation
1. For short periods of time the control
knob should be turned to ( ); the
pilot keeps burning.
2. For longer periods of time the knob
should be turned to the ( ) position;
the pilot is extinguished.
Figure 7a - Removing and replacing the
inner door
3
1
Figure 7b - Mounting the inside door
IMD 0520
3
1
IMD 0359
15