U-Line 3018CLR User Manual

U-Line 3018CLR User Manual

18" clear ice machine
Hide thumbs Also See for 3018CLR:

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE. SINCE 1962.
Modular 3000 Series
3018CLR
18" Clear Ice Machine

Advertisement

Table of Contents
loading

Summary of Contents for U-Line 3018CLR

  • Page 1 USER GUIDE SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE. SINCE 1962. Modular 3000 Series 3018CLR 18" Clear Ice Machine • •...
  • Page 2: Table Of Contents

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Contents Intro Cleaning Cleaning Condenser Safety Extended Non-Use Safety and Warning Disposal and Recycling Service Troubleshooting Installation Warranty Environmental Requirements Electrical Service Extended Cutout Dimensions...
  • Page 3 1. U-Line Customer Care must be contacted immediately at +1.800.779.2547. 2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
  • Page 4: Safety And Warning

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Safety and Warning NOTICE Please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow...
  • Page 5: Disposal And Recycling

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside.
  • Page 6: Environmental Requirements

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements.
  • Page 7 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • Page 8: Cutout Dimensions

    SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Cutout Dimensions CUTOUT DIMENSIONS PREPARE SITE Your U-Line product has been designed exclusively for a built-in installation. When built-in, your unit does not Preferred location for drain, water require additional air space for top, sides, or rear.
  • Page 9: Product Dimensions

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Product Dimensions Not Including Handle 24" (610 mm) 33-11/16" to 34-11/16" (856 mm to 881 mm) 3-5/8" to 4-5/8" 17-3/4" (450 mm) (92 mm to 118 mm)
  • Page 10: Side By Side Installation

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Side-by-Side Installation Hinge-by-Hinge Installation (Mullion) When installing two units hinge-by-hinge, 13/16" (22 mm) OTHER SITE REQUIREMENTS is required for integrated models. Additional space may be Side-by-Side Installation needed for any knobs, pulls or handles installed.
  • Page 11: Water Hookup

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Water Hookup CAUTION PREPARE PLUMBING Do not use any plastic water supply line. The line Please use the braided stainless steel water supply line is under pressure at all times. Plastic may crack which comes attached.
  • Page 12 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 4. Turn on water and check for leaks. 5. Route water supply line in cable clamp and secure with screw. Water Hookup 2...
  • Page 13: Drain

    DRAIN CONNECTION CAUTION With Trap and Vent Proper Drain If your U-Line unit did not come with a factory installed drain pump you must use a gravity A gravity drain may be used if: style drain connection. For assistance in Drain line has at least a 1"...
  • Page 14 (Optional Hook-Up) requirements for a gravity drain, you may have ordered a pre-installed U-Line P60 drain pump. Waste If you need to install a P60 drain pump into your unit, see Valve DRAIN PUMP section in the User Manual.
  • Page 15: Drain Pump

    Ice Machine ships with before installing the unit. discharge tube installed.) • The U-Line P60-00 drain pump is designed to be used 5. 2x Vent tube Zip Ties exclusively on the U-Line Clear Ice Machine and is UL recognized only for use on the U-Line Clear Ice 6.
  • Page 16 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Wiring Plug Ground Terminal Note: Slide clamp on hose end before installing hose. Do Discharge Tube Connector not tighten clamp until pump and hoses have been...
  • Page 17 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 8. Route the vent tube up CAUTION the back of the unit, next to the insulated tubes. When working with tools inside of unit, be...
  • Page 18: Anti-Tip Bracket

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Anti-Tip Bracket 5. Using a 3/32" drill bit, drill 3 pilot holes 5/8" (16 mm) deep into bottom of countertop. Use the anti-tip bracket as a template.
  • Page 19 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 5. Using a 3/32" drill bit, drill 3 pilot holes 5/8" (16 mm) deep into cabinetry frame using the anti-tip bracket as a template. 6. Install the 3 remaining #8x5/8" screws into the plate using a #2 Phillips head screwdriver.
  • Page 20: General Installation

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE General Installation INSTALLATION 1. Plug in the power/electrical cord. 1. Use a level to confirm the unit is level. Level 2. Gently push the unit into position. Be careful not to should be placed along entangle the cord or water and drain lines.
  • Page 21: Integrated Grille / Plinth Dimensions

    3. Apply double sided tape to the backside of the integrated grill (plinth strip/base fascia). Use the diagram below for reference. U-Line recommends ™ ™ tape, a high strength bonding tape.
  • Page 22: Grille / Plinth Installation

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Grille - Plinth Installation Installing the grille (plinth strip/base fascia) REMOVING AND INSTALLING GRILLE 1. Align slots in grille (plinth strip/base fascia) rail with (PLINTH STRIP/BASE FASCIA)
  • Page 23: Door Swing

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Door Swing Wall For Integrated models that are installed adjacent to a wall, 1/4" (6 mm) 1/4" (6 mm) clearance is recommended from wall on hinge side to allow the door to open 90°.
  • Page 24: Door Stop

    3. Once cover is removed, slide hinge pin into hole as shown. Pin should slide into place, stopping the door at Your U-Line unit was shipped to you with the optional 90° 90°; if the pin does not go into the hole shown, hold pin.
  • Page 25: Door Adjust

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Door Adjustments 4. The wrap hinges on top of the door. Carefully pull wrap away and then up. See below. DOOR ALIGNMENT AND ADJUSTMENT Align and adjust the door if it is not level or is not sealing properly.
  • Page 26 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Alignment and Adjustment Procedure 1. Using a T-25 Torx Bit, loosen each pair of Torx head screws on both the upper and lower hinge plates.
  • Page 27: First Use

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE First Use All U-Line controls are preset at the factory. Initial startup requires no adjustments. NOTICE U-Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line.
  • Page 28: Control Operation

    Select CUSTOMER MENU The 3000 Series of U-Line undercounter refrigeration appliances contains a feature rich customer menu. The Customer Menu allows access to a series of advanced Power features including Energy Saver Mode, Sabbath Mode,...
  • Page 29 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 3000 Series - Customer Menu Energy Saver Mode Energy Saver Mode Select Select Indicator WELCOME TO THE CUSTOMER MENU. USE ICE PRODUCTION UP/DOWN ARROWS TO (12m remaining) SCROLL SETTINGS.
  • Page 30 RETURN TO MENU LANGUAGES ENGLISH 4. Press to confirm your choice. Down The U-Line 3000 Series of models supports a number of Fahrenheit / Celsius display languages including English, Spanish, French, Select German and Italian. RETURN TO MENU FARENHEIT/CELSIUS 1.
  • Page 31 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Clean Cycle To activate Silent Mode: 1. Press to select “Silence?”. Select RETURN TO MENU CLEAN CYCLE 2. Press . Silent Mode will now begin.
  • Page 32 SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Help Select RETURN TO MENU Help Model 3018CLR 1-800-779-2547 Down To access the Help Menu, select “Help” from the Customer Menu. Press to scroll through available information.
  • Page 33: Ice

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Your clear ice machine is pre-set to produce ice between the optimal dimensions illustrated below: ICE CUBE THICKNESS ADJUSTMENT Cube Types NOTICE 1/4" TO 1/2"...
  • Page 34 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE ICE ADJUST Select RETURN TO MENU ICE ADJUST ICE ADJUST = 0 Down Adjust ice thickness as follows: 1. Press and hold for 5 seconds to enter the Customer Menu.
  • Page 35: Sabbath Mode

      Sabbath Mode Select Down U-Line Clear Ice Machine models are Star-K certified and can be used during the Sabbath. View a full list of Star-K certified U-Line units at www.star-k.org. To prepare the unit for the Sabbath: 1. Press and hold the until the unit turns off.
  • Page 36: Airflow And Product Loading

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit will not perform as expected.
  • Page 37: Cleaning

    ® monthly. For best results use Claire Stainless Steel Polish and Cleaner, which can be purchased from U-Line Rinse the interior using a soft sponge and clean water. Corporation (Part Number 173348). Comparable products are acceptable. Frequent cleaning will remove surface contamination that could lead to rust.
  • Page 38 Standpipe Water trough U-Line Ice Machine Cleaner is used to remove lime scale 6. Clean the Interior Bin as follows: and other mineral deposits. Refer to the following steps to initiate the self-cleaning cycle.
  • Page 39 Due to variations in water quality or inadequate maintenance your unit may become excessively coated in lime scale or calcium. U-Line offers a cost effective refresh kit which replaces many interior components and will return your unit to like new condition. Refresh kits may be ordered from your local distributor and installed by your local service company.
  • Page 40: Cleaning Condenser

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille (plinth strip/base fascia) free of dust and lint, and clean the condenser when necessary.
  • Page 41: Extended Non-Use

    SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Extended Non-Use VACATION/HOLIDAY, PROLONGED SHUTDOWN For questions regarding winterization, please call U-Line at +1.800.779.2547. The following steps are recommended for periods of extended non-use: CAUTION 1. Remove all consumable content from the unit.
  • Page 42: Troubleshooting

    • Compressor: The compressor makes a hum or pulsing sound that may be heard when it operates. BEFORE CALLING FOR SERVICE If you think your U-Line product is malfunctioning, read • Evaporator: Refrigerant flowing through an evaporator the CONTROL OPERATION section to clearly understand may sound like boiling liquid.
  • Page 43 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Problem Possible Cause and Remedy No Ice Ensure water is being supplied to the unit. Production Verify the ice making unit is turned on. Not Enough Ice Ensure the condenser coil is clean and free of any dirt or lint buildup.
  • Page 44: Warranty

    God, such as fire, floods, wind, and U-Line product to be free from defects in materials and lightning; damages incurred or resulting from shipping, workmanship for a period of five years from the date of improper installation, unauthorized modification, or purchase.
  • Page 45 7. If a product defect is discovered during the applicable warranty period, you must promptly notify either U-Line at 8900 N. 55th Street, Milwaukee, Wisconsin 53223 USA or at +1.800.779.2547 or the dealer from whom you purchased the product. In no event shall such notification be received later than 30 days after the expiration of the applicable warranty period.
  • Page 46: Wire Diagram

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Wire Diagram Wire Diagram 1...
  • Page 47: Product Liability

    U-Line in an unaltered condition. The dealer would then be authorized to • When the unit is ready for pickup, contact U-Line at permanently replace the end-user’s product at no cost to +1.800.779.2547 and U-Line will make arrangements the end-user.
  • Page 48: Warranty Claims

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Warranty Claims warranty status. We also accept the following information to verify warranty status: The following information defines the parameters for filing a warranty claim: •...
  • Page 49: Ordering Replacement Parts

    Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
  • Page 50: System Diagnosis Guide

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE System Diagnosis Guide REFRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly below Very hot...
  • Page 51: Compressor Specifications

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Compressor Specifications DANGER OVERLOAD PROTECTOR Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when servicing this unit.
  • Page 52: Troubleshooting Extended

    DC outputs located on the relay/power board. Included in this section is some diagnostic tips and as always, if additional help is required please contact the U-Line Corp, “Customer Care Facility” at +1.800.779.2547 for assistance. NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components.
  • Page 53 Go to component testing and turn off fill valve, level unit if needed. Low Ice Production Dirty evaporator, dirty condenser, faulty bin Clean the evaporator using U-Line cleaner, clean the condenser coil if thermistor needed, check bin thermistor reading in service mode. Ice Does Not Fall...
  • Page 54 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE REFRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly below Very hot Very hot...
  • Page 55 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE MAIN CONTROL ALL ERRORS The main control board is very robust and is rarely the Number cause of system issues. It is important to fully diagnose...
  • Page 56 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 2. Press 3. Press to scroll through available information. 4. To clear the error log, press to select “Clear Errors” and press to confirm. The refrigerant vapor leaving the evaporator travels through the suction line to the compressor inlet.
  • Page 57 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Control Operation - Service TO ENTER THE MAIN SERVICE MENU TO GO TO NEXT SUB-MENU ITEM YOU MUST ARROW UP TO “RETURN TO MENU” PRESS AND HOLD...
  • Page 58 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE SERVICE MENU The All Errors option keeps record of any system errors. When an error occurs it is recorded to all errors. The In addition to a feature rich customer menu, the 3000...
  • Page 59 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Description Solution Description Status Time To Water Clean unit with 37050 cleaner. Water Valve Used Clean circulation Pump Circulation Pump Used system Harvest Harvest Used requires cleaning.
  • Page 60 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE To access Input Status Condenser Fan (Not Used) Cabinet Lighting 1. Use Down to select “Input Status”. Cabinet Lighting (Not Used) Water Valve Pump Circulation Pump 2.
  • Page 61 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Offsets Self Test Select Select RETURN TO MENU RETURN TO MENU OFFSETS SELF TEST ZONE = 1°F NO ERRORS EVAP = 1°F try “RELAY TOGGLE”...
  • Page 62 3018R Down 10.0 NOTICE 10.5 Before altering model selection, U-Line customer service must be notified. Failure to notify The graph below shows a unit’s cooling cycle over time customer service will result in voiding of the with various differentials. manufacturer warranty. Call U-Line Customer Service for assistance.
  • Page 63 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE To alter model setting The system will create a file named “uline.csv” on the flash disk. In the event the file already exists, new data 3.
  • Page 64 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Showroom Mode Communication PC Link PC TTY Select Flash USB Flash Drive RETURN TO MENU Note: Unit ships in PC link mode. SHOWROOM MODE Down Showroom displays a number of features and allows the unit to be powered on without running the cooling system.
  • Page 65: Control Defaults

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Control Defaults Default Value Fahrenheit/Celsius* °F °C Defrost Duration Minutes Next Defrost Hours Thermistor Four OFFSET** — Thermistor Three OFFSET** — Thermistor Two OFFSET** —...
  • Page 66: Service Mode

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Service Mode QUICK GUIDE TO GO TO NEXT SUB-MENU ITEM TO ENTER THE MAIN SERVICE MENU YOU MUST ARROW UP TO “RETURN TO MENU” PRESS AND HOLD...
  • Page 67 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE SERVICE MENU The All Errors option keeps record of any system errors. When an error occurs it is recorded to all errors. The In addition to a feature rich customer menu, the 3000...
  • Page 68 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE To clear the error log use Down to select “Clear Errors” To access Relay Status and press Select to confirm. 1. Use Down to select “Relay Status”.
  • Page 69 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE To access Relay Toggle 3. Use Up and Down to scroll through available information. 1. Use Down to select “Relay Toggle”. To exit the Input Status menu use Up to select “Return...
  • Page 70 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Self Test NOTICE Customer care MUST be notified and approve of Select any changes to the differential before they are made. Failure to notify customer care will void RETURN TO MENU the warranty.
  • Page 71 RE-SELECT MODEL # with various differentials. 3018R Down NOTICE Before altering model selection, U-Line customer service must be notified. Failure to notify customer service will result in voiding of the manufacturer warranty. Call U-Line Customer Service for assistance. Re-Select Model allows the unit’s model configuration to Factory Default be modified.
  • Page 72 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE For information on identifying each data point, see the 2. Press Up or Down to scroll through each “Communication Data” table on page 17. available model.
  • Page 73 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 5. Press Select to confirm. If set to “on” showroom mode will begin immediately. To exit showroom mode press and release Power To exit the showroom mode menu use Up...
  • Page 74 USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Communication Data ID Table (Sample Temperatures in F) Field Time Condenser Ambient Current Live Temp Temp Temp Temp Zone Point Sample 1525 Data Field Zone...
  • Page 75: Thermistor 1

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Thermistors If you change a thermistor in the unit please re-apply die electric grease to the connection. If you encounter a dirty Thermistors are used for various temperature readings.
  • Page 76: Defrost

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Defrost These models have no defrost options. Defrost 1...