≤ 3,5 kW
> 3,5 kW
G
NOTE!
The supply voltage should be consistent with the rated voltage of the air conditioner.

11. CONNECTING THE ELECTRICAL CABLES.

11.1 Connecting the electrical cables for the SC33xx models.

a.
4,5 Meter cable for electrical connection between indoor and outdoor unit is delivered with the pac-
kage and is included in the refrigerant piping sleeve (indoor unit).
B.
The electrical cable is provided with an electrical quick connector.
c.
The outdoor unit is also provided with electrical quick connector.
d.
Remove the control cover from the outdoor unit by loosening the screw.
e.
Click the connector of the interior unit into the connector of the exterior unit and secure the cable
to the terminal block with the cable clamp mounted on it.
f.
The earth cable must be connected directly to the metal plate on which the terminal strip is mounted.
The location is indicated with the symbol
Cover
Cover plate
Figure 17
g.
Only connect the power supply cable once the entire installation of the air conditioner has been
completed.
G
TAKE CARE
For models with a capacity < 4.5 kW plug the plug into a wall socket.
For models with a capacity > 4.5 kW connect the power supply cable directly the power source.
Do not use a plug and socket as the high current can damage both the terminals of the plug and
the socket and even cause a fire.
4
58
58
Input Rated Current
Power supply
230V~50Hz
230V~50Hz
Power cord size
(Switch/Fuse)
16A
16A slow
2,5 mm
2
2,5 mm
2