INSTALLATION
Use the bracket for normal installation. The unit may be mounted directly on the wall, without
the bracket, only if the following three conditions are not;
•
The mounting height 3.0 m (9'10").
•
Horizontal direction adjustment is unnecessary.
•
The ground is level.
2-1
MOUNTING WITH BRACKET
Using the bracket makes it possible to adjust the unit horizontally by ±90°.
In cases where the ground is uneven and/or not parallel with the base of the unit, it is possible
to adjust the unit vertically by ±20°.
90°
Remove the Up-Down lock screw.
1
Loosen the adjustment screw two turns.
3
Adjustment screw
Caution>>
Do not loosen the
screw too much.
It may disassemble.
90°
20°
20°
2
4
In
- 6 -
Caution>>
Do not change the detection
length with bracket.
Use the masking seal to
adjust the detection length.
Push the shaft cover clip straightforwardly with
your thumb. In case the clip is stuck, use a
suitable tool. e.g. back side of a screw driver.
Shaft cover
Shaft cover clip
Tilt the bracket about 45° and pass
through the wire.