Specifications - Optex HX-40 Installation Instructions Manual

High mount outdoor detector
Table of Contents

Advertisement

7

SPECIFICATIONS

7-1
SPECIFICATIONS
Model
Detection method
PIR Coverage
PIR distance limit
Detectable speed
Sensitivity
Power input
Current draw
Alarm period
Warm-up period
Alarm output
Tamper output
Trouble output
Aux input
LED indicator
RF interference
Operating temperature
Environment humidity
Weatherproof
Mounting
Mounting height
Bracket adjust angle
Weight
Accessories
*Specifications and designs are subject to change without prior notice.
HX-40
Passive infrared
12.0 m (40') 85° wide / 94 zones
4.0 m, 5.5 m, 9.0 m (13'1", 18'1", 29'6")
0.3 m/s – 1.5 m/s (1'/s – 4'11"/s)
2.0°C (3.6°F) at 0.6 m/s
35 mA (max.)
at 12 V DC
Approx. 60 sec. (LED blinks)
Form C 28 V DC 0.2 A (max.)
N.C. 28 V DC, 0.1 A (max.) N.C. open when cover removed.
N.C. 28 V DC, 0.1 A (max.)
Red: Warm-up,
Red: Warm-up,
Alarm
-20 – +60°C (-4 – +140°F)
2.5 – 3.0 m (8'2" – 9'10")
Vertical: ±20° Horizontal: ±95°
600 g (21.2 oz.)
Bracket, Hood, Area masking seal, Screw (3 × 10 mm) × 2, Screw (4 × 20 mm) × 4
- 18 -
HX-40AM
Passive infrared & Microwave
9.5 – 18 V DC
40 mA (max.)
at 12 V DC
2.0 ±1 sec.
N.C. 28 V DC, 0.1 A (max.)
Red:
Warm-up, Alarm, Trouble
Green:
Alarm,
Warm-up, PIR detect, Trouble
Trouble
Yellow:
Warm-up, MW detect
No alarm 10 V/m
95% max.
IP55
Wall
HX-40DAM
50 mA (max.)
at 12 V DC
700 g (24.7 oz.)