HP N1528A Installation And User Manual page 69

Table of Contents

Advertisement

Troubleshooting
Table 6-2. Fault Symptom Codes
Message
Open Doors Fault
Open Handle Fault
No IP Address Found
No IP Address Mode
Fault
Unknown exchange
for the async
message
Drive In Error
Drive In Error
Drive In Error
Drive In Error
Motor Fault Condition
Picker Tach Errors
Bin Fetch Failure
Drive Fetch Failure
Drive Time-out Failure
Drive Status Failure
Drive In Flux Time-out
Drive Load Retry
Failed
Drive OpenDoor
Failed
Drive Close Door
Failed
Drive Communication
Error
Drive Get General
Status Fail
Drive Get Status 3 Fail
N1528A and N1529A ACL Tape Drive Installation and User's Guide—544594-003
FSC
ERP
2093
C, G
2094
C, G
20a0
C, G
20a1
C, G
20b0
C, G
20c0
C, G
20c1
C, G
20c0
C, G
20c1
C, G
3000
C, G
3002
C, G
3001
C, G
3013
C, G
3015
C, D, G
3016
C, D, G
3017
C, D, G
3018
C, G
3019
C, G
301A
C, G
301B
C, D, G
301C
C, D, G
301D
C, D, G
6 -9
Fault Symptom Codes (FSCs)
Door open sensor time-out detected when
open door.
Failed to open handle.
SMC router failed to get an IP address.
SMC router failed to detected static or ip
address Mode.
Unexpected exchange detected when
process Messages.
Control failed to set SCSI id.
Control failed to installed drive.
Control failed to set SCSI id.
Control failed to installed drive.
One of the motors has been disabled and
could not be re-enabled.
Picker Tach errors were detected when
checking slots.
Loader failed to fetch a cartridge from a
bin.
Loader failed to fetch a cartridge from the
drive.
Loader detects unload command time-
out.
Detected drive error from fetch, stow and
wait for handle ok drive operation.
Time-out waiting for drive to clear the flux
status.
LTO drive fail to load, detected in drive
task.
Failed open door.
Failed close drive door.
Intertask send, receive failed.
Drive communication failed.
NOT USED

Advertisement

Table of Contents
loading

This manual is also suitable for:

N1529a

Table of Contents