Optional Blower Installation - Napoleon BGNV42N Installation And Operation Instructions Manual

Millivolt system vented natural and propane gas fireplace
Table of Contents

Advertisement

10

OPTIONAL BLOWER INSTALLATION

INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be electrically connected and grounded in accord-
ance with local codes. In the absence of local codes, use the
current CSA C22.1
CANADIAN ELECTRICAL CODE
ANSI/NFPA 70
NATIONAL ELECTRICAL CODE
FIGURE 20
The three slots allow ease
of adjustment of the blower.
For a quiet running blower,
do not allow the assembly
to sit on the firebox base.
FIGURE 21
Slide the vibration reducing pad (A) into the clip and onto
the threaded stud (B) at the other end, piercing a hole into
the pad. The blower must be able to be positioned entirely
onto the pad.
Tilt the blower onto its side. Slide it past the controls and
into the clip (C). Secure to the threaded stud using the lock
washer and wing nut provided. Ensure that the blower
does not touch the fireplace base or the firebox.
B
A
FIGURE 22
W415-0377 / 03.04.03
in Canada or the
in the United States.
ADJUSTMENT
SLOTS
C
FIGURE 23
Attach the connectors from the black and white wires to the
thermodisc and secure the thermodisc bracket to the secur-
ing stud at the bottom left of the unit using a lock washer and
wing nut. Ensure that the thermodisc touches the firebox
wall.
FIGURE 24
Attach the connectors from the black and red wires to the
blower.
Attach and secure the variable speed switch using the nut
provided. Plug the harness cord into the receptacle.
FIGURE 25
The wire harness provided in this kit is a universal
harness. When installed, ensure that any excess
wire is contained, preventing it from making con-
tact with moving or hot objects.
Because the blower is thermally activated, when
turned on, it will automatically start approximately
15 minutes after lighting the fireplace and will run
for approximately 30-45 minutes after the fireplace
has been turned off. Use of the fan increases the
output of heat.
Drywall dust will penetrate into the blower bear-
ings causing irreparable damage. Care must be
taken to prevent drywall dust from coming into
contact with the blower or its compartment. Any
damage resulting from this condition is not cov-
ered by the warranty policy.
THERMODISC
RECEPTACLE /
JUNCTION
B O X
GROUND
SCREW