9 OPERATION RANGE

Power Supply
The applicable voltage range for each unit is given in " the following table". The working voltage among the three phases
must be balanced within 3% deviation from each voltage at the compressor terminals. The starting voltage must be higher
than 85% of the rated voltage.
Power Supply
Model
A18BB
Indoor and Outdoor Temperature All Models
Operating
Cooling
Heating
Unit Main Power
Phase, Volts
1~220
1~230
1~240
Hz
Indoor Temp. (D.B./W.B.) (°C)
Maximum
50
32/23
50
27/-
Hz
Maximum
50
242
50
253
50
264
Minimum
21/15
16/-
25
Applicable Voltage
Minimum
198
207
216
Outdoor Temp. (D.B./W.B.) (°C)
Maximum
Minimum
43/-
-5/-
24/18
-10/-

Hide quick links: