3 SPECIFICATION (HEAT PUMP TYPE)

3.1 CS-A18BD3P / CU-A18BBP5
ITEM / MODEL
Cooling Capacity
Heating Capacity
Refrigerant Charge-less
Standard Air Volume for High Medium and Low
Speed
External Static Pressure
Air Inlet
Air Outlet
Outside Dimension (H x W x D)
Net Weight
Piping
Refrigerant
Connection
Drain
Compressor
Type, Number of Set
Starting Method
Motor
Fan
Type, Number of Set
Air Volume Control
Motor
Air-heat Exchanger
Refrigerant Control
Refrigerant Oil (Charged)
Refrigerant (Charged)
Running
Control Switch
Adjustment
Room Temperature
Safety Devices
Noise Level (Sound Pressure)
1. Cooling capacities are based on indoor temp. 27°C D.B (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temp. 35°C
D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temp. 20° CD.B (68.0° FD.B.) and outdoor air temp. 7°C D.B. (44.6°F D.B.), 6°C W.B.
(42.8°F D.B.)
ELECTRICAL DATA (50Hz)
MODEL / ITEM
Volts
Phase
Input Power
Running Current
Starting Current
Power Factor
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic
Main Body
kW
(BTU/h)
kW
(BTU/h)
m
3
m
/min
cfm
mmAq
Pa
mm
kg (lbs)
Gas
mm (inch)
Liquid
mm (inch)
mm
Type
Input
kW
Rated Output
kW
Type
Input
kW
Rated Output
kW
L
kg (oz)
dB (A)
Power level
dB
V
kW
Cool
Heat
A
Cool
Heat
A
%
Cool
Heat
Power source
Indoor Unit
CS-A18BD3P
Hi 17
Hi 600
7
69
Backward Suction
Front blow-out
270 x (780 + 100) x 650
34 (75)
O.D Ø 12.70 (1/2) Flared Type
O.D Ø 6.35 (1/4) Flared Type
Female screw RC1 (PT1)
-
-
-
-
-
Sirocco fan-2
Three-Step and Auto mode
(Remote Control)
4-pole single phase induction motor
0.15
0.085
Louvre-fin type
Capillary tube
-
-
Wired Remote Control
Thermostat (Main Body)
Internal protector for compressor, Internal thermostat for F.M, Crankcase
heater, High pressure switch, Current Transformer
Hi 37 Lo 33
Hi 52 Lo 48
CS-A18BD3P/CU-A18BBP5
Condition by JIS B 8616
220
Single
1.95
1.88
9.0
8.6
38
98
99
AC, 1~220V, 230V, 240V 50Hz
7
Outdoor unit
CU-A18BBP5
5.00
(17,100)
5.60
(19,100)
10
Rear sided Suction
Front blow-out
685 x 800 x 300
56 (123)
I.DØ 20 x 1
Hermetic-1 (Rotary), 1
Direct on-line starting
2-pole single phase induction motor
Cool/Heat 2.31/2.30
Prop. fan-1
4-pole single phase induction motor
0.045
Louvre-fin type
Capillary tube
M60 (0.67)
R-22 2.0 (71)
Cooling 54, Heating 55
Cooling 67, Heating 68
230
Single
1.95
1.88
8.9
8.4
40
95
97
-
-
-
1.5
-
0.11
-
-
240
Single
1.95
1.88
8.8
8.3
42
92
94