Heat-N-Glo 6000TRXI Installer's Manual page 14

Table of Contents

Advertisement

4. Center the Flue Restrictor on vent and secure in
place by using two self-tapping screws (see Fig-
ure 10).
5. Reinstall the Exhaust Shield.
Figure 10
3. Match the amount of vertical you have in the sys-
tem with the chart to find the appropriate position
to set the Flue Restrictor.
- CHART -
Top Vent
Top Vent
Vertical
NG
4'
1-1
Restrictor
8'
2-2
15'
3-3
20'
3-4
25'
3-4
30'
4-4
35'
4-4
40'
5-4
1
2
3
4 5
SETTINGS
1
2
3
4 5
Rear Vent
Rear Vent
LP
NG
LP
No
No
No
Restrictor
Restrictor
No
1-2
1-1
Restrictor
3-2
2-2
1-2
3-3
3-3
2-3
3-3
3-3
2-3
3-4
3-4
3-3
3-4
3-4
3-3
4-4
4-4
3-4
HORIZONTAL VENTING
Kit No.
DVK-01TRD
45-DEGREE
ELBOW
NOTE: This model is NOT tested and NOT
approved to use 45° elbows in corner instal-
lations. 90° elbows may be used in corner
installations.
Figure 11. Corner Installation
14
H Max. Run
24" (610 mm)
H
90-DEGREE
ELBOWS