Vermont Castings TPB18NV Installation And Operating Instructions Manual
Vermont Castings TPB18NV Installation And Operating Instructions Manual

Vermont Castings TPB18NV Installation And Operating Instructions Manual

Unvented gas log heater or vented decorative appliance

Advertisement

Unvented Gas Log Heater or
Vented Decorative Appliance
Models: TPB18NV/PV,
TPB24NV/PV, TPB30NV/PV
Installation and

Operating Instructions

WARNINGS
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of
life.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
700004
TPB log cover
This appliance may be installed in an
a f t e r m a r k e t , p e r m a n e n t l y l o c a t e d ,
manufactured (mobile) home, where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases.
This is an unvented gas-fired heater. It uses
air (oxygen) from the room in which it is
installed. Provisions for adequate combustion
and ventilation air must be provided.
Refer to Page 5.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future refer-
ence.
70D0004 1/13 Rev. 10

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings TPB18NV

  • Page 1: Operating Instructions

    Unvented Gas Log Heater or Vented Decorative Appliance Models: TPB18NV/PV, TPB24NV/PV, TPB30NV/PV Installation and Operating Instructions 700004 TPB log cover WARNINGS If the information in this manual is not followed exactly, a fire or explosion may result causing This appliance may be installed in an...
  • Page 2: Table Of Contents

    CONTENTS TPB Series Log Set Thank you and congratulations on your purchase of an Vermont Castings Group Gas Log Set PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE! IMPORTANT: Read all instructions and warnings carefully before starting installation.
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION TPB Series Log Set INSTALLER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. • Any change to this heater or its controls can be dangerous. • Improper installation or use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
  • Page 4: Codes

    IMPORTANT SAFETY INFORMATION TPB Series Log Set 19. Unvented gas heaters emit moisture into the living area. In most homes of average construction, this Never connect unit to private (non-utility) does not pose a problem. In houses of extremely gas wells. This gas is commonly known tight construction, additional mechanical ventilation as wellhead gas.
  • Page 5: Product Features And Specifications

    On/Off Log Switch Assembly Min.Input Max. Input The following options may be used with the millivolt con- Model Fuel Control BTU/h BTU/h trolled heater. These options are not packaged with the TPB18NV Nat. Millivolt 19,000 8,000 log set. TPB18PV Millivolt 3,000 8,000 •...
  • Page 6: Fireplace And Hearth Dimensions

    FIREPLACE and HEARTH DIMENSIONS TPB Series Log Set This appliance is for installation only in a Barriers such as the bottom of a glass door solid-fuel burning masonry or UL127 factory- frame placed in front of a gas log set can built fireplace, vent free appliance, or in change the air flow characteristics of the listed ventless firebox enclosure.
  • Page 7: Clearances And Height Requirements

    CLEARANCES and HEIGHT REQUIREMENTS TPB Series Log Set The dimensions shown in Figures 4 through IMPORTANT: If you cannot meet these minimum clear- 12 and defined in the fireplace manufacturer's ances you must operate the heater with chimney flue instructions are minimum clearances to damper open.
  • Page 8 CLEARANCES and HEIGHT REQUIREMENTS TPB Series Log Set 8" or More of Heat Resistant Materials Hood TABLE B - Heat Resistant Material Heights and Mantel Location Heat Resistant Material Requirements for Safe Installation Measurement TPB18 TPB24 / TPB30 1” or more Hood not required.
  • Page 9 CLEARANCES and HEIGHT REQUIREMENTS TPB Series Log Set 10” or less 28” Heat Resistant Material 12” Example: The bottom o f t h e m a n t e l m a y Heater in project from the wall a Fireplace or maximum of 10"...
  • Page 10: Floor Clearance

    FLOOR CLEARANCES TPB Series Log Set The gas log heater must be installed at least 1C\," above The gas log heater may be installed nearer to the floor if a any combustible flooring material, such as carpeting or minimum of 14" of noncombustible material such as slate tile, which is closer than 14"...
  • Page 11: Installation

    INSTALLATION TPB Series Log Set DAMPER STOP INSTALLATION BEFORE FULLY INSTALLING THE UNIT: A damper stop must be provided with the unit. Contact your • Turn OFF the gas supply to the fireplace or fire- dealer to obtain one. The damper stop must be installed as box.
  • Page 12: Place And Secure Appliance

    VENTED APPLIANCE INSTALLATION TPB Series Log Set PLACE AND SECURE APPLIANCE ASSEMBLY PROCEDURE: You must secure the gas log heater to the fireplace floor. If not, the entire unit 1. Center the gas log unit on the fireplace or firebox. Make certain the front of the burner sits inside the front edge may move when you adjust the controls.
  • Page 13: Gas Line Installation

    GAS LINE INSTALLATION TPB Series Log Set CONNECT THE GAS NOTICE: A qualified gas appliance installer must connect the heater to the gas supply. Consult all local codes. Use new black iron or steel pipe. Internally CHECk GAS TYPE: The gas supply must tinned copper or copper tubing can be be the same as stated on the heater’s rat- used per National Fuel Code, section 2.6.3,...
  • Page 14: Check Gas Pressure

    CHECk GAS PRESSURE TPB Series Log Set The heater gas inlet connection is a 3/8" NPT at the valve. On all control type units, the inlet connection is on the right Test Port “OUT” side of unit. To connect from the opposite side, route the pipe around the back portion of the unit.
  • Page 15: Electrical Wiring - Millivolt

    ELECTRICAL WIRING - MILLIVOLT TPB Series Log Set The Millivolt valve is a self-powered combination gas control Label all wires prior to disconnection when THAT DOES NOT REQUIRE 110V AC TO OPERATE. servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
  • Page 16: Connect Remote Receiver

    ELECTRICAL WIRING - MILLIVOLT TPB Series Log Set CONNECT REMOTE RECEIVER 1. Set remote receiver. See instructions included in receiver kit. . Connect the two () 1/4" female connectors to the TP/TH and TH terminals on the control valve. Remote Wire NOTE: Heat reduces battery life.
  • Page 17: Log Placement

    LOG PLACEMENT TPB Series Log Set Before you begin — This unit is supplied with seven (7) The positioning of the logs is critical to ceramic fiber logs. Do not handle these logs with your bare the safe and clean operation of this heater. hands.
  • Page 18 LOG PLACEMENT TPB Series Log Set Right Base Log # . Place right base log (#) on two pins on right side of grate. Figure 19 Figure 19 LG1018 Left Base Log #3 LG1018 TPB right base log LG1019 3. Place left base log (#3) on two pins on left side of grate.
  • Page 19 LOG PLACEMENT TPB Series Log Set Right Front Log #4 Figure 21 4. Place right front log (#4) on two pins on bottom right side of grate. Figure LG100 5. Place right end of left top log (#5) on bottom center grate pin. Place left end of left top log on top of the left LG1020 base log.
  • Page 20: Place Rock Wool

    LOG PLACEMENT TPB Series Log Set PLACE ROCk WOOL After installing logs, place TPB18-RW (Rock Wool) in dime- size pieces evenly across the burner surface in between the logs. Do not add additional rock wool. Refer to Figure 24 for the approximate area to place rock wool. Wash hands after placing rock wool.
  • Page 21: Riser And Steel Bar Installation

    RISER and STEEL BAR GRATE INSTALLATION TPB Series Log Set OPTIONAL RISER INSTALLATION IMPORTANT! When installing riser kit, the minimum recommended height for the firebox opening will be An optional riser is available. Place the riser in your firebox increased by 2" (the riser height). or fireplace in the desired location.
  • Page 22: Optional Cast Iron Grate & Andirons Installation

    OPTIONAL CAST IRON GRATE and ANDIRON INSTALLATION TPB Series Log Set CAST IRON GRATE INSTALLATION An optional cast iron grate is available. The grate will set in front of the riser on the fireplace floor. The grate may be used with or without the riser. Figure 28 Cast Iron Grate Cast Iron Grate FP873...
  • Page 23: Flame Appearance

    FLAME APPEARANCE TPB Series Log Set PLACE THE DECORATIVE ROCk Thermocouple for Natural DO NOT sprinkle volcanic rock on the logs, around the pilot, or on or near burners. This may cause sooting. Place volcanic rock only on the floor of the fireplace. During initial operation of the new heater, Thermocouple for LP...
  • Page 24: Operating Instructions

    OPERATING INSTRUCTIONS TPB Series Log Set OPERATING INSTRUCTIONS Avoid any drafts that alter burner flame patterns. Do The initial break-in operation should last six hours with the not allow fans to blow directly into the fireplace. Do not burner at the highest setting. Provide maximum ventilation place a blower inside the burn area of the firebox.
  • Page 25: For Your Safety Read Before Lighting

    OPERATING INSTRUCTIONS TPB Series Log Set FOR YOUR SAFETY READ BEFORE LIGHTING If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a piezo ignition device which lights the pilot. If piezo is not working properly see Match lighting Instructions, Page 27.
  • Page 26: Millivolt Control Lighting Instructions

    OPERATING INSTRUCTIONS TPB Series Log Set Millivolt CONTROL LIGHTING INSTRUCTIONS 1. STOP! Read the safety information label. . Make sure the manual shutoff valve is fully open. 3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, refer to instructions for Match lighting Instructions, Page 27.
  • Page 27: Match Lighting Instructions

    OPERATING INSTRUCTIONS / CLEANING and SERVICING TPB Series Log Set MATCH LIGHTING INSTRUCTIONS 1. Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.). . Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo button, light a match and hold the flame to the end of the pilot and ignite the pilot.
  • Page 28: Troubleshooting

    TROUBLESHOOTING TPB Series Log Set Turn off appliance and allow to cool before NOTE: All troubleshooting items are listed in order of operation. cleaning. Only a qualified service person should service and repair the heater. Problem Possible Cause Solution When ignitor button is 1.
  • Page 29: Logs

    TROUBLESHOOTING TPB Series Log Set Problem Possible Cause Solution 1. Press in control knob fully. ODS/pilot lights, but flame 1. Control knob not fully pressed in. goes out when control . After ODS/pilot lights, keep control knob . Control knob not pressed in long knob is released.
  • Page 30: Replacement Parts

    REPLACEMENT PARTS TPB Series Log Set TPB18 TPB24 TPB30 Ref. Description Qty. Natural Propane Natural Propane Natural Propane 1. Piezo Ignitor 700004 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 . Piezo Wire 00K063 00K063 00K063 00K063 00K063 00K063 TPB burner parts 3.
  • Page 31 REPLACEMENT PARTS TPB Series Log Set Ref. Description Qty. CTCL18 CTCL24 CTCL30 Rear Log #1 70D011 70D0031 70D01 700004 Right Base Log # 70D01 70D003 70D0 Left Front Base Log #3 TPB log parts 70D013 70D0033 70D03 Right Frong Log #4 70D017 70D0037 70D07...
  • Page 32: Accessories

    REPLACEMENT PARTS TPB Series Log Set ACCESSORIES Description Part Number Flex Connector Flexcon 30 Wall Switch and Wire MVWS Wall Thermostat Kit On/Off Remote RCB, RCM, WMTD Thermostat Remote RSCT, RCT, WWTD Remote Receiver Cover Ember RRCE Remote Receiver Cover Metal RRCM On/Off Touch Light Remote Remote Touch Light T-Stat...
  • Page 33 TPB Series Log Set 70D0004...
  • Page 34: Massachusetts Residence Only

    Massachusetts Residents Only — Please read and follow these special requirements TPB Series Log Set NOTE REGARDING VENTED PRODUCTS detector with an alarm shall be installed. This product must be installed by a licensed plumber or . Approved Carbon Monoxide Detectors. Each carbon gas fitter when installed within the Commonwealth of monoxide detector as required in accordance with the above Massachusetts.
  • Page 35: Warranty

    You may also have additional rights not covered in this Limited Lifetime Warranty. Vermont Castings Group reserves the right to investigate any and all claims against the Limited Lifetime Warranty and decide upon method of settlement.
  • Page 36 Vermont Castings Group 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.com...

This manual is also suitable for:

Tpb30nvTpb18pvTpb30pvTpb24nvTpb24pv

Table of Contents