Empire Comfort Systems DVCP36PP30N-1 Installation Instructions And Owner's Manual

Empire Comfort Systems DVCP36PP30N-1 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater

Advertisement

FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
If not installed, operated and maintained in
accordance with the manufacturer's instructions,
this product could expose you to substances in
fuel or from fuel combustion which can cause
death or serious illness.
WARNING
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
NOTICE: Barriers required and pre-installed on fireplace.

INSTALLATION INSTRUCTIONS

AND OWNER'S MANUAL
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING
WARNING
HOT GLASS
WILL
CAUSE BURNS.
DO NOT TOUCH
UNTIL COOLED.
NEVER
ALLOW CHILDREN
TO TOUCH GLASS.
DIRECT VENT ZERO CLEARANCE
GAS FIREPLACE HEATER
INTERMITTENT PILOT (IPI)
UL FILE NO. MH30033
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
GLASS
MODEL SERIES:
MILLIVOLT (MV)
DVCP36(PP,SP)30(N,P)-1
DVCP36(PP,SP)70(N,P)-1
GAS-FIRED
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DVCP36PP30N-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Empire Comfort Systems DVCP36PP30N-1

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. DIRECT VENT ZERO CLEARANCE WARNING GAS FIREPLACE HEATER FIRE OR EXPLOSION HAZARD MODEL SERIES: Failure to follow safety warnings exactly could result in serious injury, death or GAS-FIRED MILLIVOLT (MV) property damage.
  • Page 2 BEFORE YOU START CARTON CONTENTS & HARDWARE PACK CARTON CONTENTS - DVCP36(PP,SP)3 SERIES CARTON CONTENTS - DVCP36(PP,SP)7 SERIES Sample Warnings and Definitions: Unpacking the fireplace NOTICE: The barrier screens supplied with this fireplace may DANGER be damaged if force is applied to their surfaces. Take care not to push against barrier screens.
  • Page 3: Table Of Contents

    This fireplace is not for use with solid fuels. Improper use Junction Box Wiring Installation Instructions ..................18 Empire Comfort Systems for proper orifice size identification. of the fireplace can cause serious injury or death from fire, Installation ............................19 - 24 burns, explosions, or carbon monoxide poisoning Venting Fireplace Top ........................
  • Page 4: Specifications

    SPECIFICATIONS ACCESSORIES The following accessory parts can be obtained from your Empire Comfort Systems dealer. Contact your Empire Dealer for more NATURAL GAS accessory options. If you need additional information, contact Empire Comfort Systems Inc., 918 Freeburg Ave., Belleville, Illinois...
  • Page 5: Blower Installation

    BLOWER INSTALLATION BLOWER INSTALLATION Snap the fan control disc into the forked prongs on the valve Remove the glass and screen frames, and the bottom access panel from the side which is opposite the valve. bracket. See Figure 3. The glass and screen frame may be removed as a unit. It is not necessary to separate the screen frame from the glass frame.
  • Page 6: Fireplace Dimensions - See-Thru

    FIREPLACE DIMENSIONS - SEE-THRU FIREPLACE DIMENSIONS - PENINSULA (TO CENTER OF VERTICALLY (TO CENTER OF VERTICALLY- ORIENTED ELBOW) ORIENTED ELBOW) INDEX DVCP36SP(30,70) INDEX DVCP36PP(30,70) DIMENSION DESCRIPTION DIMENSION DESCRIPTION LETTER (Dimensions in Inches) LETTER (Dimensions in Inches) The maximum height of firebox face (excluding standoffs) 39-1/4 The maximum height of firebox face (excluding standoffs) 39-1/4...
  • Page 7: Clearances

    CLEARANCES CLEARANCES Television Considerations Mantel Chart Installing a television above a fireplace has become increasingly popular; however, the area above any fireplace gets hot and most TV manufacturers recommend against placing their products MANTEL VERTICAL FINISHED COMBUSTIBLE TRIM FRAMING WALL near a heat source.
  • Page 8: Vent Termination Clearances

    This does not include vinyl. Empire Comfort Systems Inc. assembly Information on Various Venting Routes and Components will not be held responsible for heat damage caused from...
  • Page 9: Gas Supply

    GAS SUPPLY LOCATING FIREPLACE The gas pipeline can be brought in through the vent-end of the GAS SUPPLY PRESSURE (INCHES W.C.) fireplace only. Consult the current National Fuel Gas Code, ANSI Z223.1 installation code. MINIMUM NORMAL MAXIMUM RECOMMENDED GAS PIPE DIAMETER Natural Gas 14.0 SCHEDULE 40 PIPE...
  • Page 10: Junction Box Wiring Installation Instructions

    JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS INSTALLATION Vent Runs WARNING In planning the installation for the fireplace, it is necessary to install certain components before the fireplace is completely All wiring should be done by a qualified electrician positioned and installed. These include the direct vent system, and shall be in compliance with all local, city and state RECEPTACLE BOX gas piping for the fireplace and the electrical wiring.
  • Page 11: Installation

    INSTALLATION INSTALLATION Framing If necessary, the positions of the side nailing flanges can Before placing the fireplace inside the frame work, or adjusted by loosening (but do not remove) the top and building the frame work around the fireplace, the top stand- bottom screws, anchoring the bracket in place using a center offs must be formed and secured.
  • Page 12 INSTALLATION INSTALLATION Vertical Vent Pipe Clearance 45° ELBOW WITH HORIZONTAL TERMINATION Cutting the Hole Installing Support Brackets NOTICE: Need 2-inch clearance around pipe for the first After the fireplace has been positioned in its permanent location, Install a horizontal pipe support used for each 3 feet of 12 inches above Firebox.
  • Page 13: Venting Fireplace Top

    VENTING FIREPLACE - TOP INSTALLATION (Initial 45° Elbow Oriented Upwards) Installing Firestops NOTICE: Remove insulation from the framed area in the attic FLUE RESTRICTOR Firestops are required for safety whenever the vent system before installing the firestop and/or vent pipes. passes through an interior wall, an exterior wall, or a ceiling.
  • Page 14: Top Vent System Identification

    VENTING FIREPLACE - TOP VENTING FIREPLACE - TOP TOP VENT SYSTEM IDENTIFICATION VENTING GRAPH Begin the vent system installation by selecting the type of venting When selecting a vent system for use with the fireplace, refer to be installed and the path that it will take. Verify that clearances to the “Venting Fireplace”...
  • Page 15: Horizontal Termination

    VENTING FIREPLACE - TOP VENTING FIREPLACE - TOP HORIZONTAL TERMINATION VERTICAL TERMINATION One Elbow Two Elbows No Elbows Two Elbows INSTALLED NOTICE: Subtract 3 feet from the total horizontal measurement VERTICALLY for each 90° elbow installed horizontally. Subtract 1-1/2 feet from the total horizontal measurement for each 45°...
  • Page 16 VENTING FIREPLACE - TOP VENTING FIREPLACE - TOP VERTICAL TERMINATION VERTICAL TERMINATION General Maintenance Locate and mark the center point of the vent pipe using a nail on The vertical termination cap for this fireplace must not be any Installing the Vent System in a Chase the underside of the roof.
  • Page 17: Venting Fireplace - Rear

    VENTING FIREPLACE - TOP DVVK-5F FLEX VENT INSTRUCTIONS The DVVK-5F FLEX VENT KIT includes the following VERTICAL TERMINATION components: • (1) Horizontal Termination Cap Vertical Through the Roof Applications • (1) 4-foot section of Flex vent with spacers (5in flue/8in Your Gas Fireplace has been approved for: outer pipe) with flue adapter collar a) Vertical installations up to 40 feet in height.
  • Page 18: Finishing Installation

    FINISHING INSTALLATION DVVK-5F FLEX VENT INSTRUCTIONS Use non-combustible materials where indicated for the fireplace Prior to making the vent connections, apply high temperature installation. Non-combustible materials do not ignite or burn sealant (1000°F min.) to the vent connections before as a result of using the fireplace. These include metal, brick, securing with the band clamps provided.
  • Page 19: Optional Fiber Or Porcelain Liners

    The fiber or porcelain liners sit in front (NOT behind) of the • Replacement of loose material (glowing embers) must be purchased from an Empire Comfort Systems Dealer. brick brackets as shown in Figures 61 and 62. From either side of the fireplace, remove the lower access •...
  • Page 20: Log Identification - Lsu24Spf

    Log Placement Figure 66 Replacement of glowing embers must be purchased from an FRONT VIEW - COMPLETED LOG SET INSTALLATION Empire Comfort Systems Dealer. Application of excess glowing (WITHOUT EMBERS) embers may adversely affect performance of the fireplace. Log F...
  • Page 21 LOG PLACEMENT - LSU24SPF LOG PLACEMENT - LSU24SPF Place Log A on to burner pins 7, 8, 9, 10 and 11. Refer to the images on this page. Place Log H on to burner tabs 6 and 2. Place Log J onto burner tab 3. Refer to the images on this page. Page 40 36092-2-0316 36092-2-0316...
  • Page 22 LOG PLACEMENT - LSU24SPF LOG PLACEMENT - LSU24SPF Place Log I onto burner tab 1 and the left pin on Log E. Place Log F onto burner tab 5 and the right pin on Log E. Refer to the Place Log E onto burner tab 4 and the pin on Log A. Refer to the images on this page. images on this page.
  • Page 23 LOG PLACEMENT - LSU24SPF LOG PLACEMENT - LSU24SPF Place Log B onto burner tab 13 and left pin on Log A. Place Log C onto burner tab 14. Place Log K onto burner tabs 12 and 16. Refer to the images on this page. Page 44 36092-2-0316 36092-2-0316...
  • Page 24 LOG PLACEMENT - LSU24SPF LOG & STONE IDENTIFICATION - DG30MX Part Log placement is complete. Refer to the images on this page. A bag of “wood splinters” and vermiculite is included with your log set Description Front View Top View Number and may be arranged on the false floor to suit your preference.
  • Page 25 Log P 36041 Log Placement Figure 69 Replacement of glowing embers must be purchased from an Empire Comfort Systems Dealer. Application of excess glowing embers may adversely affect performance of the fireplace. FRONT VIEW - COMPLETED LOG SET INSTALLATION (WITHOUT EMBERS)
  • Page 26 LOG & STONE PLACEMENT - DG30MX LOG & STONE PLACEMENT - DG30MX Place Stone A onto burner pins 7 and 8. Place Stone B onto burner pins 9 and 10. Place stone C onto burner pin 11 and burner tab Place Stone F onto burner tab 1.
  • Page 27 LOG & STONE PLACEMENT - DG30MX LOG & STONE PLACEMENT - DG30MX Place Stone E onto burner tab 13. Place Stone D onto burner tab 16. Place Stone H onto the false floor as shown below. Refer to Place Log P onto burner tab 2 and center pin on Stone B. Place Log L onto burner tab 4 and pin on Stone G. Refer to the images the images on this page.
  • Page 28 LOG & STONE PLACEMENT - DG30MX LOG & STONE PLACEMENT - DG30MX Place Log O onto burner tab 14 and left pin on Stone B. Place Log N onto burner tab 3 and right pin on Stone B. Refer to the Place Log J onto burner tab 6 and pin on Stone E.
  • Page 29: Millivolt Standing Pilot Operating Instructions

    LOG & STONE PLACEMENT - DG30MX MILLIVOLT STANDING PILOT OPERATING INSTRUCTIONS Log and Stone placement is complete. Refer to the images on this page. A bag of “wood splinters” and vermiculite is included with Millivolt System The OWNER should carefully read and follow these operating your mixed logs and stone set and may be arranged on the false floor to suit your preference.
  • Page 30: Millivolt Standing Pilot Wiring Diagram

    MILLIVOLT STANDING PILOT OPERATING INSTRUCTIONS MILLIVOLT STANDING PILOT WIRING DIAGRAM STANDING PILOT OPERATING INSTRUCTIONS Installation of Remote Receiver (OPTIONAL) THERMOSTAT REMOTE/OFF/ON Switch Place remote receiver on the floor of fireplace behind the louver The fireplace is equipped with a REMOTE/OFF/ON switch. A wire as far forward as possible.
  • Page 31: Millivolt Standing Pilot Lighting Instructions

    MILLIVOLT STANDING PILOT LIGHTING INSTRUCTIONS MILLIVOLT STANDING PILOT TROUBLESHOOTING With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you FOR YOUR SAFETY READ BEFORE LIGHTING do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
  • Page 32: Intermittent Pilot Electronic System Operating Instructions

    INTERMITTENT PILOT ELECTRONIC SYSTEM WIRING DIAGRAM INTERMITTENT PILOT ELECTRONIC SYSTEM OPERATING INSTRUCTIONS 5.25 VDC ELECTRONIC CONTROL VALVE NOTICE: The gas control has a manual HI/LO flame adjustment The electronic control valve system includes the ability to switch knob (regulator) that allows you to increase or decrease the the pilot from a standing pilot mode to an intermittent pilot mode.
  • Page 33: Intermittent Pilot Lighting Instructions

    INTERMITTENT PILOT LIGHTING INSTRUCTIONS INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FOR YOUR SAFETY READ BEFORE LIGHTING Brief Description of the Components Troubleshooting The gas valve is fitted with a manual HI/LO knob to allow for Before proceeding with the procedures in the following troubleshooting table, verify that the power supply (AC/DC manual modulation of the gas outlet pressure to the fireplace WARNING...
  • Page 34 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING Page 66 36092-2-0316 36092-2-0316 Page 67...
  • Page 35: Maintenance And Service

    MAINTENANCE AND SERVICE MAINTENANCE AND SERVICE Wiring Glass Cleaning Glass Removal and Replacement Separating Screen Frame From Glass Frame If any of the original wire as supplied with this fireplace must Remove bottom access panel. Turn glass and screen frame assembly upside down and rest WARNING be replaced, it must be replace with no.
  • Page 36: See-Thru Parts View

    PARTS VIEW PARTS LIST SEE-THRU SEE-THRU INDEX INDEX DESCRIPTION DESCRIPTION PART NUMBER PART NUMBER 36051 36051 STAND-OFF, LONG R11127 R11127 CONTROL BOARD / MODULE 36053 36053 NAILING FLANGE, TOP 29382 29382 MODULE TRAY 36074 36074 GLASS FRAME ASSEMBLY R11122 R11122 BATTERY HOLDER 36076 36076 SCREEN FRAME ASSEMBLY...
  • Page 37: Peninsula Parts View

    PARTS VIEW PARTS LIST PENINSULA PENINSULA PART NUMBER PART NUMBER INDEX INDEX DESCRIPTION DESCRIPTION 36051 36051 STAND-OFF, LONG R10882 R10882 ELBOW, 3/8 NPT X 3/8 FLARE 36053 36053 NAILING FLANGE, TOP R9760 R9760 PIEZO IGNITOR 36052 36052 STAND-OFF, SHORT R3436 R3436 SWITCH 36074...
  • Page 38: Master Parts Distributor List

    Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair individuals. parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. • Any safety screen, guard, or barrier removed to service a Safety Precautions fireplace must be replaced prior to operating the fireplace.
  • Page 39: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP GAS REQUIREMENTS FOR MASSACHUSETTS Propane (LP-Gas) is a flammable gas which can cause fires SOME POINTS TO REMEMBER For all side wall horizontally vented gas fueled equipment SIGNAGE. A metal or plastic identification plate shall be and explosions.
  • Page 40: Appliance Service History

    Service Performed/Notes Empire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the periods specified below. Hearth products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 41 Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 80 36092-2-0316...

This manual is also suitable for:

Dvcp36sp30p-1Dvcp36pp70n-1Dvcp36sp70p-1

Table of Contents