PRODUCT INSTALLATION, WIRING, AND BATTERY
4. Connect a jumper wire (reference gray) between the negative (–) terminal
on battery B to the positive (+) terminal on battery A.
IMPORTANT: The jumper wire should be the same wire gauge as the
negative (–) and positive (+) power cables.
5. Connect the trolling motor negative (–) lead to the negative (–) terminal on
battery A.
6. Starting with the positive (+) lead, reconnect the battery cables to the
engine starting battery.
d
Battery A
24-volt battery connection
a -
Power cables to trolling motor
b -
Manual reset circuit breaker
c -
Jumper wire (not supplied)
d -
Negative (–) battery terminal
IMPORTANT: Do not connect a common ground bond cable between 24‑volt
and 12‑volt electrical circuits.
36-VOLT BATTERY CONNECTION
1. Starting with the negative (–) lead, disconnect the battery cables from the
engine starting battery.
2. Install a 50‑amp (good) or 60‑amp (best) manual reset circuit breaker in
line with the trolling motor power cable positive (+) lead and the trolling
motor battery C positive (+) terminal.
3. Connect the positive (+) trolling motor lead to the positive (+) terminal on
trolling motor battery C.
INFORMATION
c
Battery B
BLK
c
b
16
a
37824
eng