22. Press
until the 001 DATA_TRANS_EXE item displays.
1
PEM
005
001
DATA_TRANS_EXE
23. For the DATA_TRANS_EXE item, press
data value to 1 to execute the update.
NOTE: A warning message indicating the TV cannot be
turned off displays.
PEM
005
001
DATA_TRANS_EXE
DO NOT POWER OFF
Warning
Message
Displays
After the update is complete, the data value changes back to
0 and a message indicating the data transter was successful
displays.
24. Proceed to "Verifying the Emitter Output Level".
KDL-46NX810/55NX810/55NX811/60NX810
SERVICE
LDRV_CHANGED
0
3
to increase the
SERVICE
LDRV_CHANGED
1
SERVICE ADJUSTMENTS

2-2-5. VERIFYING THE EMITTER OUTPUT LEVEL

If necessary, the emitter LED output level can be increased or decreased.
25. Press
PEM
009
000
26. Using the table below, press
decrease the data value.
27. Press MUTING then press
28. Exit Service Mode by turing the TV Power Off.
29. Proceed to "Verifying the Model and Panel Information".
Data Value
until the 009 3D category displays.
2
SERVICE
3D
EMIT_STR
to increase or press
3
DATA VALUE
SETTING
0
Strong (Default)
1
to WRITE (Save) the changes.
0
0
Default
Data Value
to
6
Weak