2. Operating in manual mode
When the VisorALARM PLUS 2U receiver has no Automation Software connected or the Automation
Software has failed, the receiver must be operated in manual mode.
In manual mode signals must be visualized and acknowledged from the receiver through the receiver
LCD and keypad.
When a signal arrives at the receiver in manual mode, the LCD shows a status line as follows:
If you are not logged into the VisorALARM PLUS 2U receiver when events are received pressing the
ACK key for the first time will display the highest priority event and silence the receiver piezo. If the
ACK key is pressed a second time you will be prompted for a password. Upon entering the password
the event with the highest priority is resounded. Repeatedly pressing the ACK key will now display
and acknowledge subsequent events.
Subsequently the signal information is shown in the display with the next format:
The LCD shows the following information:
§
hh:mm:ss: The hour, minutes and seconds of the alarm in a 24 hours format
§
aaaaaaaa: The eight digit account code
§
Q: Qualificator, E= New event or opening; R=Restoration or closing; P=Status report.
§
XYZ: Event code
§
GG: Number or group or partition.
§
CCC: Zone number or user identifier.
§
TTTTTTT: Textual description for the event code. This contemplates the following values:
PRIMARY VisorALARM
1 Signal pending
16:33:23 00001234
E110 01 001 Fire
hh:mm:ss aaaaaaaa
QXYZ GG CCC TTTTTTTTT
Event Code
TTTTTTT
10x
Medical
11x
12x
13x
14x, ..., 1Fx
2xx
3xx
Trouble
4xx
Opn/Cls
VisorALARM PLUS 2U Operating
III - 7
»
»
Fire
Panic
Burglar
Alarm
Superv
Doc.DM375-I
Ver.1.0
Need help?
Do you have a question about the VisorALARM PLUS 2U and is the answer not in the manual?
Questions and answers