Philips DVDR3590H Service Manual page 76

Hide thumbs Also See for DVDR3590H:
Table of Contents

Advertisement

http://www.jdwxzlw.com/?fromuser=华盛维修
EN 76
5.
3139 785 32804
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
家电维修资料网,免费下载各种维修资料
Firmware Upgrading & Diagnostic Software
DS_ASP_Watchdog
1618
This nucleus configures the watchdog timer of the ASP, and waits till the
watchdog expires. The watchdog time-out is 10 seconds. On expiry of the
watchdog timer, the ASP switching off, and on its power supply, and resets the
main controller.
So, this nucleus will not return an error code when the test succeeded, but the
system will restart again.
-
Configure watchdog timer.
-
Wait till the watchdog expired.
10 seconds.
None
Number
Description
161801
IIC-bus communication failed.
161802
The ASP did not reset the host processor.
DS:> 1618
Waiting till the watchdog expires.
Factory Diagnostics and Service Software
DVD Video Recorder (Sep 10 2004, 08:11:24)
Version
:662
Release
:C1_1
Baseline :F_C1_195
DS:>
DS_ASP_Reboot
1619
This command forces a reboot of the main controller. The ASP shutdown the
digital board power supply and then switch it on to force reset.
So, this nucleus will not return an error code when the test succeeded, but the
system will restart again.
-
Send command reboot to ASP.
2 seconds.
None
Number
Description
161901
IIC-bus communication failed.
161902
The ASP did not reset the host processor.
DS:> 1619
Factory Diagnostics and Service Software
DVD Video Recorder (Sep 10 2004, 08:11:24)
Version
:662
Release
:C1_1
Baseline :F_C1_195
DS:>
Build
:20040910_0515
Buildtype :no
Variant
:verum:dvdrw2_lib
Build
:20040910_0515
Buildtype :no
Variant
:verum:dvdrw2_lib

Advertisement