Firmware Upgrading & Diagnostic Software
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example (Chrysalis)
Example (Leco)
家电维修资料网,免费下载各种维修资料
DS_SYS_BuildInfoGet
1236
Retrieve the software build information of the Diagnostics & Service application
-
Show the information that is stored in the DVDR_BuildInfoType structure
Less than 1 second
None
Number
Description
123600
Retrieving build info succeeded
123601
Retrieving build info failed
DS:> 1236
123600:
Version
:1091
Build
:20050823_0630
Release
:SG1_1
Buildtype :dev
Baseline
:SGP29atl#SG1_1_20050609_base
Variant
:genlecoplus
Test OK @
DS_SYS_UartSetup
1237
Set up a configuration for the selected UART
-
Parse user input
-
Use MIS_UART_Setup to setup the selected UART with the requested
parameters
Less than 1 second
The user inputs 6 parameters:
<UartNr><baudrate><flowcontrol><databits><parity><stopbits>
UartNr:
1=UART port 1 : not used (Chrysalis only)
2=UART port 2 : Bit Engine or DTTM (Chrysalis only)
3=UART port 3 : Analogue board
baudrate:
115200,62500,57600,38400,19200,9600,4800,2400,1200
flowcontrol:
0=disabled 1=enabled
databits:
7 or 8
parity:
"NO", "ODD" or "EVEN"
stopbits:
1 or 2
Number
Description
123700
Setting up the selected UART succeeded
123701
User provided Invalid setup parameters
123702
Setting up the selected UART Failed
123703
Selected UART is not available
DS:> 1237 2 38400 0 8 NO 1
123700:
Test OK @
DS:> 1237 2 38400 0 8 NO 1
123703: The selected UART is not available
Error @
3139 785 32804
5.