9. Technical specifications for Devireg™ 530, 531, and 532
Operation voltage
Power consumption
Relays:
• Resistive load
• Inductive load
Sensing unit
Sensing values:
• 0°C
• 20°C
• 50°C
Hysteresis
Ambient temperature
Frost protection
240 VAC +10/ -20, 50 Hz
Max. 0.25W
240V ~ 15A
cos φ = 0.3 Max. 4A
NTC 15 kOhm at 25°C
42 kOhm
18 kOhm
6 kOhm
+/- 0.2°C
-10° to +30°C
5°C