Diagnostics
A spanner symbol and LCD fault code will appear automatically if there is a fault in the temperature measuring
system, defrost system, fans or low ambient heater. (Refer diagram below)
When the PC door is opened an alarm will sound, the number of beeps also indicates the fault code. Pressing
any of the control buttons can deactivate these alarms.
Example: When a fault develops, the LCD fault code appears with the spanner.
After rectifying the problem, the fault code and spanner will disappear. Faults are only rectified when that
feature is used. So in the case of a defrost fault, the code will remain until a defrost is initiated and it is
successful.
4.2

Fault Codes

Fault Code 1
Reason:
Primary Action:
Fault Code 2
Reason:
Primary Action:
Fault Code 3
Reason:
Primary Action:
Secondary Action:
Tertiary Action:
Fault Code 4
Reason:
Primary Action:
Secondary Action:
Tertiary Action:
Fault Code 5
Reason:
Primary Action:
Secondary Action:
Fault Code 6
Reason:
Primary Action:
Secondary Action:
On the last power up, the power module failed self test.
Replace power module.
The previous 2 defrosts were aborted after 30 minutes.
Check defrost element assembly in the FC. If faulty replace.
The resistance of all the temperature sensors is outside the normal range. (> 45K
Ohms)
Check the 6-way RAST connector at the power module.
Re-terminate the 6-way RAST connector.
Replace power module.
The resistance of all the temperature sensors is outside the normal range. (< 660
Ohms)
Check the 6-way RAST connector at the power module.
Re-terminate the 6-way RAST connector.
Replace power module.
The resistance of the FC sensor is outside the normal range (> 45K Ohms).
Check the sensor connection at the power module.
Replace the sensor.
The resistance of the FC sensor is outside the normal range (<660 Ohms).
Check the sensor connection at the power module.
Replace the sensor.