Air Handling Parts; Cover (At The Top); Air Guide And Blower; Fan And Shroud - Friedrich CP10 Service & Parts Manual

Room air conditioner chill 115 volts
Table of Contents

Advertisement

Air handling parts

2.2 AIR HANDLING PARTS
2.2.1. AIR GUIDE AND BL OWER
1. Remove the front grille.
2. Remove the cabinet.
3. Remove the control box.
4. Remove the 3 screws which fasten the brace.
5. Remove the brace.
6. Remove the 2 screws which fasten the evaporator.
7. Move the evaporator forward and pulling it upward
slightly. (See Figure 20)
8. Move the evaporator to the left carefully.
9. Pull out the hook of orifice by pushing the tabs and
remove it. (See Figure 21)
10. Remove the clamp with a hand plier which
secures the blower.
11. Remove the blower.
12. Remove the 4 screws which fasten the air guide
from the barrier.
13. Move the air guide backward, pulling out from the
base pan.
14. Re-install the components by referring to the
removal procedure, above.

2.2.2 FAN AND SHROUD

1. Remove the cabinet.
2. Remove the brace.
3. Remove the 3 screws which fasten the condenser.
4. Move the condenser to the left carefully.
5. Remove the clamp which secures the fan.
6. Remove the fan and then pull out the shroud.
(See Figure 22)
7. Re-install by referring to the removal procedure.
Figure 20
Figure 21
Figure 22
—6—

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp12Cp06Cp08Ep08Ep12Cp10g10a ... Show all

Table of Contents