Placing The Ember Material; Step 12 Before Lighting The Fireplace; Step 13 Lighting The Fireplace; After The Installation - Heat-N-Glo SL-350TV Installer's Manual

B-type vent gas fireplace
Table of Contents

Advertisement

Placing the Ember Material

Ember material is shipped with this gas fireplace. The bag
labeled Glowing Ember (050-721) is standard glowing ember
material. To place the ember material:
• Remove the mesh or open the glass doors (if equipped).
• Place dime size pieces of ember material about 1/2 inch
apart near port holes in burner top. Do NOT press em-
bers into burner ports. Cover the top of the burner with a
single layer of ember material. For best performance do
NOT place embers on the ports at the rear of the burner
(see Figure 15).
• Save the remaining ember materials for use during fire-
place servicing. The bag of embers provided is sufficient
for 3 to 5 applications.
• Replace the mesh or close the glass doors (if equipped)
on the unit.
Figure 15. Placement of the Ember Material
CAUTION: THE MESH MUST BE ON OR THE OP-
TIONAL GLASS DOORS CLOSED BEFORE OPERAT-
ING THE UNIT.
Step 12. Before Lighting the Fireplace
Before lighting the fireplace, be sure to do the following:
Remove all paperwork from underneath the fireplace.
Review safety warnings and cautions
• Read the Safety and Warning Information section at
the beginning of this Installers Guide.
Double-check for gas leaks
• Before lighting the fireplace, double-check the unit for
possible gas leaks.
Double-check vent terminations and front grilles for
obstructions.
• Before lighting the fireplace, double-check the unit for
possible obstructions that could be blocking the vent ter-
minations or the front grilles.
EMBER MATERIALS
Double-check that grate shipping support was re-
moved (see page 16).
• Make sure that the grate is resting directly on the refrac-
tory.
Double-check for faulty components
• Any component that is found to be faulty MUST BE re-
placed with an approved component. Tampering with the
fireplace components is DANGEROUS and voids all war-
ranties.
A small amount of air will be in the gas supply lines. When
first lighting the fireplace, it will take a few minutes for the
lines to purge themselves of this air. Once the purging is
complete, the fireplace will light and will operate normally.
NOTE: The fireplace should be run for 8 hours on the initial
start-up. This will help to cure the chemicals used in the
paint and logs.
Subsequent lightings of the fireplace will not require this
purging of air from the gas supply lines, unless the gas
valve has been turned to the OFF position, in which
case the air would have to be purged.
Step 13. Lighting the Fireplace
You’ve reviewed all safety warnings, you’ve checked the
fireplace for gas leaks, you know the vent system is
unobstructed, and you’ve checked for faulty components.
Now you’re ready to light the fireplace.
WARNING: PLEASE REFER TO THE USER’S
!
MANUAL FOR ALL CAUTIONS, SAFETY, AND
WARNING INFORMATION PERTAINING TO THE
LIGHTING AND OPERATION OF THE FIREPLACE.

After the Installation

LEAVE THIS INSTALLATION MANUAL WITH
!
THE APPLIANCE FOR FUTURE REFERENCE.
17

Advertisement

Table of Contents
loading

Table of Contents