・ When voltage increases, connect the constant-voltage power
supply and check the voltage at Level 3 ("Battery exhausted").
Then, turn off the power, increase the voltage in increments of
0.1V and turn the SW from OFF to ON. Measure the voltage
under the following conditions.
(When voltage changes, be sure to turn off the power.)
・ Level 1 : The battery mark is turned off on the monitor LCD.
Level 1 : The battery mark is turned off on the monitor LCD.
・ Level 2 : The battery "half" mark lights on the monitor LCD.
Level 2 : The battery "half" mark lights on the monitor LCD.
Judgment standards
- R0 ・ S20 -