13. X9A socket
The X9A socket receives the thermistor connector (only for
installations with domestic hot water tank).
14. Pump fuse FU2 (in line fuse)
15. Pump relay K4M
16. Transformer TR1 for PCB power supply
17. A4P digital I/O PCB (only for installations with solar kit or digital
I/O PCB)
18. Conduit hole to pass through the booster heater power supply
cable.
19. Conduit hole to pass through the booster heater power supply
cable and the thermal protection cable.
20. Conduit hole to pass through the room thermostat cable and
2-way valve and 3-way valve control cables.
21. Conduit hole to pass through the thermistor cable and user
interface cable (and benefit kWh rate cable).
22. Conduit hole to pass through the backup heater power supply
wiring.
23. Conduit hole to pass through optional I/O PCB connection
wiring.
24. K7A relay for solar pump (optional)
This relay and its output on X2M can be activated when the solar
input on A4P becomes active.
25. Terminal for expansion vessel heater and, only for EDL and EBL
units, plate heat exchanger heater and switch box heater.
NOTICE
The electrical wiring diagram can be found on the inside of
the switch box cover.
E(D/B)(H/L)Q011~016BB
Unit for air to water heat pump system
4PW67904-1 – 01.2011
6.
I
NSTALLATION

6.1. Selecting an installation location

WARNING
Be sure to provide for adequate measures in order to
prevent that the unit be used as a shelter by small
animals.
Small animals making contact with electrical parts can
cause malfunctions, smoke or fire. Please instruct the
customer to keep the area around the unit clean and
clear.
Carry
out
the
consideration
earthquakes.
Improper installation work may result in accidents due
to fall of equipment.
The equipment is not intended for use in a potentially
explosive atmosphere.
Be sure that sufficient precautions are taken, in
accordance with the applicable legislation, in case of
refrigerant leakage.
CAUTION
Do not install the unit in places such as the following:
Where there is mist of mineral oil, oil spray or vapour.
Plastic parts may deteriorate, and cause them to fall
out or water to leak.
Where corrosive gas, such as sulphurous acid gas, is
produced.
Corrosion of copper pipes or soldered parts may
cause the refrigerant to leak.
Where
there
electromagnetic waves.
Electromagnetic waves may disturb the control
system, and cause malfunction of the equipment.
Where flammable gases may leak, where carbon fibre
or ignitable dust is suspended in the air or where
volatile flammables, such as thinner or gasoline, are
handled.
Such gases may cause a fire.
Where the air contains high levels of salt such as that
near the ocean.
Where voltage fluctuates a lot, such as that in
factories.
In vehicles or vessels.
Where acidic or alkaline vapour is present.
Install the unit, power wire and connecting wire at
least 1 meter away from televisions or radios to
prevent image interference or noise.
(Depending on the radio waves, a distance of 1 meter
may not be sufficient to eliminate the noise.)
specified

installation

work
of
strong
winds,
typhoons,
is
machinery
which
Installation manual
in
or
emits
12