Mitsubishi Electric PWFY-P100VM-E-BU Data Book page 10

Hide thumbs Also See for PWFY-P100VM-E-BU:
Table of Contents

Advertisement

Model
Power source
Heating capacity
(Nominal)
Power input
Current input
Temp. range of
Outdoor temp.
heating
Inlet Water temp.
Cooling capacity
(Nominal)
Power input
Current input
Temp. range of cooling
Outdoor temp.
Inlet Water temp.
Connectable
Total capacity
outdoor unit
Model / Quantity
Noise level (measured in anechoic room)
Diameter of
Liquid
refrigerant pipe
Gas
Inlet
Diameter of
water pipe
Outlet
Field drain pipe size
External finish
External dimension H × W × D
Net weight
Circulating water
Operation Volume
Range
Design pressure
R410a
Water
External
Drawing
Wiring
Document
Standard attachment
Accessory
Optional parts
Remark
Note:
*1 Nominal heating conditions
Outdoor Temp. : 7°CDB/6°CWB (45°FDB / 43°FWB)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 30°C
* Due to continuing improvement, the above specifications may be subject to change without notice.
* The unit is not designed for outside installations.
* Please don't use the steel material for the water piping material.
* Please always make water circulate or add the brine to the circulation water when the ambient temperature becomes 0°C or less.
* Please always make water circulate or pull out the circulation water completely when not using it.
* Please do not use groundwater and well water.
*1
kW
*1
kcal / h
*1
Btu / h
kW
A
W.B
W.B
-
*2
kW
*2
kcal / h
*2
Btu / h
kW
A
D.B
D.B
-
dB<A>
mm(in.)
mm(in.)
mm(in.)
mm(in.)
mm(in.)
mm
in.
kg(lb)
m
/h
3
MPa
MPa
*2 Nominal cooling conditions
Outdoor Temp. : 35°CB (95°FDB)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 23°C
Water flow rate 2.15m
/h
3
* The water circuit must use the closed circuit.
1-phase 220-230-240V 50/60Hz
-20~32°C (-4~90°F) PURY - series
-20~15.5°C (-4~60°F) PUHY - series
-5~43°C (23~110°F) PURY - series
-5~43°C (23~110°F) PUHY - series
50~100% of outdoor unit capacity
PURY-P200YHM-A(-BS)~PURY-P400YHM-A(-BS)
PURY-P450YSHM-A(-BS)~PURY-P800YSHM-A(-BS)
PURY-EP200YHM-A(-BS)~PURY-EP300YHM-A(-BS)
PURY-EP400YSHM-A(-BS)~PURY-EP600YSHM-A(-BS)
PUHY-P200YHM-A(-BS)~PUHY-P450YHM-A(-BS)
PUHY-P500YSHM-A(-BS)~PUHY-P1250YSHM-A(-BS)
PUHY-EP200YHM-A(-BS)~PUHY-EP300YHM-A(-BS)
PUHY-EP400YSHM-A(-BS)~PUHY-EP900YSHM-A(-BS)
800 (785 without legs) × 450 × 300
31-1/2" (30-15/16" without legs) × 17-3/4" × 11-13/16"
Installation Manual, Instruction Book
Strainer, Heat insulation material, 2 × Connector sets
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and
other items shall be referred to the Installation Manual.
Water flow rate 1.93m
* Install the unit in an environment where the
wet bulb Temp. will not exceed 32degC.
* Please do not use it as a drinking water.
- 3 -
PWFY-P100VM-E-AU
12.5
10,800
42,700
0.015
0.068 - 0.065 - 0.063
10~40°C (50~104°F)
11.2
9,600
38,200
0.015
0.068 - 0.065 - 0.063
10~35°C (50~95°F)
29
Φ9.52 (Φ3/8") Brazed
Φ15.88 (Φ5/8") Brazed
PT3/4 Screw
PT3/4 Screw
Φ32 (1-1/4'')
NO
35 (78)
0.6~2.15
4.15
1.00
WKB94L763
E00C223
NONE
Unit converter
kcal
= kW × 860
Btu/h = kW × 3,412
cfm
= m
/min × 35.31
3
/h
3
lb
= kg / 0.4536
* The specification data is subject
to rounding variation.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pwfy-p100vm-e-auPwfy-p200vm-e-au

Table of Contents