2 BUS data cables up to 50 meters in length are used to
connect to the series and zone regulator, allowing the device
to:
• control up to one zone;
• enter two ambient temperature values, one for the daytime
(comfort temp.) and one for the night (lower temp.);
• control the temperature of the domestic hot water (in
conjunction with a water heater Unit);
• select the operating mode for the heating and hot water
production functions of each individual hydraulic circuit:
- comfort temperature mode,
- low temperature mode,
- adjustable antifreeze temperature mode;
• control the boiler delivery temperature according to the ou-
tdoor temperature (in conjunction with the external probe),
with climatic curve settings;
• obtain information about the system:
- temperature of the system,
- operating mode,
- meter data,
- timer program,
- pump operating status,
- variable input values and operation;
VICTRIX 50

ZONE CONTROLLER (CE 3.015264)

The zone controller only operates in conjunction with the
series regulator. Besides the functions described for the series
thermoregulator, it allows the user to keep all the important
information concerning the operation of the appliance and
heating system under control and particularly ready to hand.
This means that the previously set parameters can be easily
modified without having go go to the place where the series
regulator is installed. the climatic timer-thermostat built
into the remote control panel allows the system's delivery
temperature to be adapted to the effective needs of the place
being heated so as to obtain the required ambient temperature
with the utmost precision and, thus, with evident savings in
running costs. The controller also allows the ambient tempe-
rature and effective outdoor temperature to be displayed (this
latter if the external probe is installed). The zone controller is
powered by the series thermoregulator by means of 2 BUS
data cables.
SPECIFICATIONS
• enter the operating parameters:
- operating times,
- operating mode,
- domestic hot water,
- direct, mixed 1, mixed 2 circuits,
- date and time;
• display operating faults with their relative error codes by
means of the check-control system;
• display the date, time, day of the week and temperature of
the generator.