THERMOREGULATION
Cascade and zones regulator
General features.
e Cascade and zones regulator allows the user to control, monitor
and program the operating sequence of the generators connected. e
regulator can be set-up and programmed using parameters that gua-
rantee ideal temperature conditions at all times of the day and night
and throughout every day of the week for both the heating system and
domestic hot water system (when VICTRIX 50 is used in conjunction
with a water heater). e cascade and zones regulator can be fitted into
a support affixed to a wall.
e electrical connections are made with 2 wires powered at 230V
(1.5 mm 2 ) in diameter.
2 BUS data cables up to 50 meters in length are used to connect to the
boiler, allowing the device to:
• control up to three zones (2 of which mixed if necessary) and a sepa-
rate water heater unit. Since up to 5 cascade regulator can be installed
(of which only one, the so-called Master, will be connected to the
boiler board), systems with up to a total 15 zones (of which 10 mixed
if necessary) and 5 separate water heater units can be controlled;
• enter two ambient temperature values, one for the daytime (comfort
temp.) and one for the night (lower temp.);
• control the temperature of the domestic hot water (in conjunction
with a water heater Unit);
• select the operating mode for the heating and hot water production
functions of each individual hydraulic circuit:
- comfort temperature mode or low temperature mode, adjustable
antifreeze temperature mode;
• control the boiler delivery temperature according to the outdoor
temperature (in conjunction with the external probe), with climatic
curve settings;
• obtain information about the system:
- temperature of the system, operating mode, meter data, timer
program, pump operating status, variable input values and ope-
ration;
• enter the operating parameters:
- operating times, operating mode, domestic hot water, direct, mixed
1, mixed 2 circuits, date and time;
• display operating faults with their relative error codes by means of
the check-control system;
• display the date, time, day of the week and temperature of the gene-
rator.
STV50 ed 04/04
VICTRIX 50
General features.
e Zone manager only operates in conjunction with the Cascade
and zones regulator. Besides the functions described for the Cascade
and zones regulator, it allows the user to keep all the important infor-
mation concerning the operation of the appliance and heating system
under control and particularly ready to hand. is means that the
previously set parameters can be easily modified without having go
go to the place where the cascade regulator is installed. the climatic
timer-thermostat built into the remote control panel allows the sy-
stem's delivery temperature to be adapted to the effective needs of the
place being heated so as to obtain the required ambient temperature
with the utmost precision and, thus, with evident savings in running
costs. e controller also allows the ambient temperature and effective
outdoor temperature to be displayed (this latter if the external probe
is installed). e zone manager is powered by the cascade regulator
by means of 2 BUS data cables up to 50 meters in length are used to
connect to the boiler, allowing the device to:
• control up to one zone;
• enter two ambient temperature values, one for the daytime (comfort
temp.) and one for the night (lower temp.);
• control the temperature of the domestic hot water (in conjunction
with a water heater Unit);
• select the operating mode for the heating and hot water production
functions of each individual hydraulic circuit:
- comfort temperature mode or low temperature mode, adjustable
antifreeze temperature mode;
• control the boiler delivery temperature according to the outdoor
temperature (in conjunction with the external probe), with climatic
curve settings;
• obtain information about the system:
- temperature of the system, operating mode, meter data, timer
program, pump operating status, variable input values and ope-
ration;
• enter the operating parameters:
- operating times, operating mode, domestic hot water, direct,
mixed 1, mixed 2 circuits, date and time;
• display operating faults with their relative error codes by means of
the check-control system;
• display the date, time, day of the week and temperature of the
generator.
1
Zone manager
ermoregulation VICTRIX 50

Advertisement

Table of Contents
loading

Summary of Contents for Immergas VICTRIX 50

  • Page 1 is means that the previously set parameters can be easily modified without having go domestic hot water system (when VICTRIX 50 is used in conjunction go to the place where the cascade regulator is installed. the climatic with a water heater).
  • Page 2 Junction clamp Junction box Picture 4: Star network of bus data. e earth connection must be effected on one side of the star! STV50 ed 04/04 ermoregulation VICTRIX 50...
  • Page 3: Electrical Connection

    1 regulator mixed circuit 2 IV° direct circuit cascade mixed circuit 1 regulator mixed circuit 2 V° direct circuit cascade mixed circuit 1 Pic. 6 regulator mixed circuit 2 STV50 ed 04/04 ermoregulation VICTRIX 50...
  • Page 4: Bus Address

    Sensor and bus data cables cannot be layed together with electrical supply wires of other electrical appliances. - For the connection it is necessary to use the special connec- tion terminals (X1÷X4) provided separately. STV50 ed 04/04 ermoregulation VICTRIX 50...
  • Page 5 10. With more regulators connected (at least five) the regulator directly connected to the boiler must have the bus address 10. For the other regulators, the addresses must follow numbers 20, 30, 40 e 50. STV50 ed 04/04 ermoregulation VICTRIX 50...
  • Page 6: Auto-Set Function

    If the first start-up is registered a change in the configuration of the sensors can be effectued only manually or cutting off the power supply to the regulator. STV50 ed 04/04 ermoregulation VICTRIX 50...
  • Page 7 Room temperature MC 2 not reached 56-4 BUS data: Address addresses conflict 70-0 Activity no signal 70-1 EEPROM 71-0 EEPROM faulty 71-1 Boiler errors: Error block* E-XX Error block* B-XX * see the boiler instruction manual STV50 ed 04/04 ermoregulation VICTRIX 50...
  • Page 8 Configuration for the connection in cascade. With VICTRIX 50 boiler and cascade regulator it is possible Use of the cascade and zones regulator for installa to connect in cascade up to three boilers as shown in the tions in cascade.
  • Page 9 Concerning the electrical connection of the components to the cascade regulator, see the following scheme: Pic. 12 STV50 ed 04/04 ermoregulation VICTRIX 50...
  • Page 10 Pic. 13 Address 0 (1st boiler) Address 1 (2nd boiler) Address 2 (3rd boiler) e parameters for the functioning in cascade are already set into the "cascade" menu of the regulator. STV50 ed 04/04 ermoregulation VICTRIX 50...
  • Page 11 e cascade and zones regulator can be used even with one connections are shown in picture 15. single VICTRIX 50 boiler to manage up to three heating zones. Pic. 14 STV50 ed 04/04...
  • Page 12 Pic. 15 STV50 ed 04/04 ermoregulation VICTRIX 50...

Table of Contents