Electrical Needs
The N'FINITY System requires a dedicated 110-volt 20-amp circuit. The unit draws a large amount of amps at initial start up. By
designating a dedicated circuit breaker, you will guarantee the unit has enough power to run effectively. Contact an electrician for
assistance with the installation of this dedicated electrical circuit:
1.
Match the electrical outlet to the plug provided on the N'FINITY unit.
2.
Provide a dedicated circuit and wiring for the unit.
Electrical Outlet
Plug your N'FINITY unit into a surge protector or power conditioner. As with any sensitive electrical equipment, the N'FINITY
electrical equipment may be damaged by power surges and spikes. Power surges and spikes are not covered in the N'FINITY warranty.
WE RECOMMEND THAT YOU DO NOT USE A GROUND FAULT INTERRUPTER (GFI) WITH THIS PRODUCT.
Testing the Unit Prior to Installation
Carefully remove your N'FINITY unit from the box. Do not destroy your packaging material, as it provides the only safe
means of transporting the unit. Place the N'FINITY system on a tabletop to prepare it for installation and testing. Plug
system into a live electrical outlet and turn unit on. The system may take up to 10 to 15 minutes before operating correctly,
meaning all four fans are running. Cold air coming out on cellar side, hot air coming out on exhaust side. Once the
operation has been tested, turn the unit off, and unplug the unit from the electrical outlet.*
* Note: If the system does not seem to be fully functional after 15 minutes, please refer to the Troubleshooting Guide on page 15.
Location of Supply and Return Grilles
Locate the supply and return grilles inside the cellar to create an airflow pattern that maximizes air circulation in the room. Avoid short
circulation of the air.
DO NOT:
Install through-the-wall return air grilles at floor level, as they will collect dust from the floor.
Mount the unit lower than 18" from the top of the room.
Locate the supply or return air grille where it is blocked by bottles, boxes or cases
Units weigh 75-85 pounds and are cumbersome for one person to carry. We recommend that you get someone else to help you during
the installation process. NEVER LAY UNIT ON ITS SIDE.
Page 6

PRE-INSTALLATION

WE 081313