N'Finity 3000 User Manual

N'Finity 3000 User Manual

N'finity 3000 wine cellar cooling unit
Hide thumbs Also See for 3000:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for N'Finity 3000

  • Page 2 Copyright © 2011. N'FINITY and Wine Enthusiast are registered trademarks of Wine Enthusiast Companies. All rights reserved. This manual, the product design, and the design concepts are copyrighted by Wine Enthusiast, with all rights reserved. Your rights with regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the United States of America.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Introduction ........2 Receiving &...
  • Page 4: Introduction

    If you have any questions about your N'FINITY unit, please call us at 1-800-648-6058. This owner's manual is intended to assist in the proper installation and maintenance of the N'FINITY cooling system. In order to ensure the longevity of your cooling unit, the equipment should be installed correctly and have a proper care and maintenance schedule.
  • Page 5: Quick Reference Guide

    QUICK REFERENCE GUIDE Front / Side View Air sensor Controller Power cord (front location optional) Rear / Side View Power cord (rear location standard) Access door Drain line tube www.wineenthusiast.com Page 3...
  • Page 6: Preparing The Wine Cellar

    PREPARING THE WINE CELLAR The performance and life of your N'FINITY unit are contingent upon the steps you take in preparing the wine cellar. Improperly preparing your enclosure or incorrectly installing your N'FINITY unit may cause unit failure, leaking of condensation, and other negative side effects.
  • Page 7 Mounting the Unit The unit must be mounted within 18 inches of the ceiling in order to achieve sufficient cooling. As the room cools down, the warm air will rise to the ceiling. Mounting the unit high in the room will create a consistently cool environment by capturing the warm air and replacing it with cool air.
  • Page 8: Installation

    However, you must have a fresh air inlet as well. NOTE: If you are unsure whether you have adequate ventilation in your install location, please contact us to assess your specific installation at 1-800-648-6058. N'FINITY's Airflow Circulation BACK - EXHAUST ROOM FRONT - WINE CELLAR N’FINITY...
  • Page 9: Pre-Installation

    The N'FINITY System requires a dedicated 115-volt, 20-amp circuit. The unit draws a large amount of amps at initial startup. Match the electrical outlet to the plug provided on the N'FINITY unit and provide a dedicated circuit and wiring for the unit.
  • Page 10: Airflow Control

    AIRFLOW CONTROL Airflow Options The magnetic deflectors can be used to mount the system lower in the cellar, flush-mount the condenser side of the system, or direct the airflow to avoid recirculation. Simply apply the magnetic deflectors in one of the positions displayed below. Choose the option that will best suit your installation.
  • Page 11: Preparing The Installation Location

    PREPARING THE INSTALLATION LOCATION Minimum Tools Needed: Level Hammer Screwdriver Locate the desired installation location (no lower than 18 inches from the ceiling). Using a stud finder, locate the studs on either side of the center point, and mark them with vertical lines. Using a level and a pencil, mark a horizontal line on the wall between the two studs, no less than 11/2 inches and no more than 18 inches from the ceiling.
  • Page 12: Installing The System

    INSTALLING THE SYSTEM Single-Piece Mounting Bracket The unit utilizes a single-piece mounting bracket. This sturdy bracket frames the installation location and secures the unit to the wall. Applying Insulation Tape Locate the four (4) precut pieces of black foam tape included with the system, two larger pieces and two smaller pieces.
  • Page 13: Drain Line

    DRAIN LINE Condensation Drain Line Tube The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location. It is important that the drain line tube be properly connected and used to prevent leakage and other problems associated with excess condensation.
  • Page 14: System Operation

    Set Point wait five minutes before reenergizing the relay. This prevents The set point is preset at the factory (N'FINITY) to 55°F. It the compressor from repeatedly turning off and on. If the can be adjusted by the customer between 50°F and 70°F (in unit is calling for cooling during this time, the compressor 1°F increments).
  • Page 15: Controller Functions

    CONTROLLER FUNCTIONS Menu Navigation & Value Increase Power On/Off (Press and hold to (hold for approx. 3 seconds) manually enter defrost mode.) & Escape Menu Navigation Probe Value & Alarm & Value Decrease Folder (Press and hold to enter the parameter menu.) Compressor On Alarm is Present...
  • Page 16 Alarm The alarm symbol is shown when the unit encounters an issue that needs attention. The displayed alarm codes are explained below. The alarm code will remain displayed until corrected. Alarm Codes Message Cause Solution 1-800-648-6058 Faulty air-sensing probe Contact Customer Service at The air probe is sensing a 1.
  • Page 17: Controller Wiring Schematic

    CONTROLLER WIRING SCHEMATIC www.wineenthusiast.com Page 15...
  • Page 18 NOTES Page 16 WE 060517...
  • Page 19: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Unit has ice forming on the evaporator Possible cause Solution Evaporator filter and/or coil are dirty. Clean filter and coil with a vacuum. If coil is very dirty, use a spray bottle with a small amount of liquid dish detergent. Spray coil, let set for five minutes, and then flush with fresh water.
  • Page 20 TROUBLESHOOTING GUIDE Unit leaks water Possible cause Solution Unit is not level Unit should be level in wall to prevent leakage Drain line clogged or kinked Check drain line to make sure water can flow freely Drain is clogged, preventing water from escaping 1.
  • Page 21: Maintenance Schedule

    MAINTENANCE SCHEDULE Monthly 1. Check for unusual noise or vibration 2. Check drain line for proper drainage and make sure there is no mold growth Every Six Weeks Using the supplied drain line brush, clean the interior drain line leading from the drip tray and drop a pan tab into the drip tray (see illustration below for more details).
  • Page 22: Technical Assistance

    The customer service representative will be able to assist you with your questions and warranty information more effectively if you provide them with the following: • The model and serial number of your N'FINITY unit. • Location of unit and installation details, such as ventilation, ducting, construction of your wine cellar, and room size.
  • Page 23: Installation Terms & Conditions

    PRODUCT WARRANTY INFORMATION 1. N'FINITY Product Base Terms Wine Enthusiast Companies is in the business of manufacturing and selling wine cabinets, cooling units and related goods; each such wine cabinet, cooling unit and related good is referred to herein as a "Product". As used herein, the term "Wine Enthusiast"...
  • Page 24 End User must follow the required installation, use and maintenance procedures set forth by Wine Enthusiast in N'FINITY's Owner's Manual. The Owner's Manual is shipped with each Product and if another copy is needed, replacement copies can be downloaded from Wine Enthusiast's website (www.WineEnthusiast.com) or by contacting Wine Enthusiast directly for a new copy of the Owner's Manual.
  • Page 25: Wine Enthusiast Companies

    6. Customer Service and Troubleshooting Wine Enthusiast's technical support department is available to answer and questions or inquiries for End Users regarding a N'FINITY Product, as well as to assist in performing basic troubleshooting, Monday through Friday, from 9:00 a.m. to 6:00 p.m. EST, at telephone number 1-800-648-6058.
  • Page 26: Wine Enthusiast Companies

    Wine Enthusiast Companies 333 North Bedford Rd., Mt. Kisco, NY 10549 1-800-648-6058 www.wineenthusiast.com...

This manual is also suitable for:

4200

Table of Contents