SYSTEM OPERATION - VERSION 1 CONTROLLER
FOR SYSTEMS PURCHASED PRIOR TO JUNE 2012
NOTE: Confirm if you have a Version 1 Controller using the
above illustration as a guide. If Your controller does not match this
illustration than you have a Version 2 Controller featured on page 10.
Initial Start-Up
When power is applied to the unit, the control will briefly display all symbols.
Normal System Cycle
After the unit or cellar has reached the set point, unit will turn off until temperature rises above set temperature (all units
are shipped with the set point of 55°F and a differential of 4°F).
Anti Short Cycle
The Anti Short Cycle ensures that the unit will remain off for a period of 5 minutes after the unit has reached the set point
to allow the pressure in the refrigeration system to equalize prior to starting the compressor.
Defrost Cycle
The Defrost Cycle is a precautionary measure, as icing or frosting of the coil does not occur during normal operation. The
system will go through a defrost cycle every 2 hours. During the defrost cycle, unit shuts down.
Air Sensor
Each N'FINITY cooling unit comes equipped with an air sensing probe. The air sensing probe senses the temperature of
the cellar air and cycles the unit on and off based on the desired cellar temperature.
Note: The desired cellar temperature is the temperature set by you.