Various Information During The Process - Skyrc D100 Balance Charger

Ac/dc dual balance charger/discharger
Hide thumbs Also See for D100:
Table of Contents

Advertisement

OPERATING PROGRAM
R : 3 S E R
S : 3 S E R
C O N F I R M ( E N T E R )
START/ENTER
L P 4 s 1 . 5 A 1 2 . 1 4 V
B A L 0 0 0 : 5 0 0 0 0 2 2

VARIOUS INFORMATION DURING THE PROCESS

Press INC or DEC during charging or discharging process, you can inquire various
information on LCD screen .
L P 4 s 1 . 5 A 1 2 . 1 4 V
B A L 0 0 0 : 5 0 0 0 0 2 2
INC
4 . 0 7 4 . 0 6 4 . 1 1 V
0 . 0 0 0 . 0 0 0 . 0 0 V
INC
F u e l = 9 0 %
C e l l = 4 . 1 0 V
L P 4 s 1 . 5 A 1 2 . 1 4 V
B A L 0 0 0 : 5 0 0 0 0 2 2
DEC
DEC
DEC
Ext. Temp
----
Int. Temp
37 C
DEC
Temp Cut-Off
   
50 C
DEC
DEC
· 14
R shows the number of cells detected by the charger and S is the
number of cells set by you at the previous screen. If both numbers
are identical, press START/ENTER to start charging process.
7. Charging Status Monitor
During charge process, real-time status will be showed as left screen.
Real-time status: battery type, battery cell, charge current, battery
voltage, elapsed time and charged capacity
Voltage of each cell in the battery pack when the battery is
connected with balance lead.
Charged capacity percentage and average cell voltage of the
battery pack.
Final voltage when the program ends.
Input voltage.
Internal temperature.
Temperature probe is needed to show external temperature.
Cut off temperature
Safety timer ON and duration of time in minutes.
Capacity cut-off ON and the setting value of capacity.
D100

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents