5.2 Engine – Putting into operation after scheduled out-of-service-
period
Preconditions
☑ Engine is stopped and starting disabled.
Putting into operation
Item
Lube oil system
Coolant circuit
Coolant circuit
Fuel prefilter
Battery-charging generator
drive
Engine Control Unit ECU
Engine Interface Module EIM Check plug connections (→ Page 136).
Engine Monitoring Unit EMU Check plug connections (→ Page 135).
46 | Operation | MS150060/04E 2016-02
Action
Check engine oil level (→ Page 103).
Check coolant level (→ Page 115).
Heat engine coolant with coolant preheating unit.
Drain water and contaminants (→ Page 92).
Check condition of drive belt (→ Page 123).
Check plug connections (→ Page 134).